This paper was converted on www.awesomepapers.org from LaTeX by an anonymous user.
Want to know more? Visit the Converter page.


Sympathetic cooling of 113Cd+ by laser-cooled 40Ca+ in a linear Paul trap for Microwave Ion Clocks

J. Z. Han1,2, H. R. Qin1,2, L. M. Guo1, N. C. Xin1, H. X. Hu1, Y. M. Yu3, V. A. Dzuba4111Email: [email protected], J. W. Zhang1222Email: [email protected], and L. J. Wang1,2333Email: [email protected] 1State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing 100084, China 2Department of Physics, Tsinghua University, Beijing 100084, China 3Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China 4School of Physics, University of New South Wales, Sydney, 2052, Australia
(Received date; Accepted date)
Abstract

We report sympathetic cooling of 113Cd+ by laser-cooled 40Ca+ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113Cd+ ions was achieved. The temperature of these ions was measured at 90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10172\times 10^{-17}. Up to 4.2×1054.2\times 10^{5} Cd+ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^{5} Cd+ ions present, indicating that this Ca+–Cd+ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10175.4(0.5)\times 10^{-17} using a high-accuracy ab initio approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

I Introduction

With the development of atomic clock technology, atomic clocks have played an important role in both basic physics Dzuba-NP-2016 ; Safronova-RMP-2018 ; Wcislo-NA-2016 and practical applications Hinkley-science-2013 . Because of their long-term stability and relatively simple structure, microwave clocks play an irreplaceable role in areas such as satellite navigation Bandi-EL-2011 , deep space exploration Prestage-IEEE-2007 ; Tjoelker-PTTI-2012 , and time keeping Diddams-science-2004 . To date, cesium fountain clocks have reigned supreme in state-of-the-art performance regarding frequency uncertainty. Uncertainties have been reduced to the 101610^{-16} level, the main limitation being collision shifts, black-body radiation (BBR) shifts, and cavity phase shifts Weyers-Metrologia-2018 . Among microwave atomic clocks, those based on ions have attracted extensive research because of unique advantages. First, ion clocks have small collision shifts because of the strong Coulomb repulsion between ions. Second, ions confined in the trap occupy a small space volume, making it easier to measure the temperature with high precision by reducing the uncertainty associated with BBR shifts. Third, ion clocks need no microwave cavity, and therefore uncertainties from cavity phase shifts do not arise. In fountain clocks, such shifts arise from the asymmetry of the electric fields in the microwave cavity when atoms move up and down.

To date, 113Cd+ Jelenkovic-PRA-2006 ; KMiao-OL-2015 , 171Yb+ Phoonthong-APB-2014 ; Mulholland-APB-2019 , and 199Hg+ Berkeland-PRL-1998 ; Burt-ITUFFC-2016 ions have been used in the development of microwave ion clocks. A great deal of progress has been achieved. In the past ten years, our group has been committed to developing a microwave atomic clock based on 113Cd+ KMiao-OL-2015 ; JWZhang-PRA-2012 ; SGWang-OE-2013 ; JZHan-EPJD-2019 ; YNZuo-APL-2019 ; JZHan-PRA-2019 . At present, the short-term frequency instability has reached 6.1×1013/τ6.1\times 10^{-13}/\sqrt{\tau}, and the uncertainty associated with ground-state hyperfine splitting has reached 6.6×10146.6\times 10^{-14} KMiao-OL-2015 . Currently, the fundamental limitation halting further improvements in accuracy and stability of microwave ion clocks are the second-order Doppler shifts (SODSs), and the Dick effect resulting from dead times during interrogations JWZhang-CPL-2015 .

In the past few years, sympathetic-cooling technology has greatly advanced the development of the optical ion clock. Optical ion clocks based on Mg+ sympathetic cooling of Al+ have become one of the most accurate atomic clocks in the world Brewer-PRL-2019 . This cooling technology cools the target ions continuously to a lower temperature through Coulomb interactions with the coolant ion. Sympathetic cooling could be an effective method to overcome the limitations on stability and accuracy of microwave ion clocks. The application of sympathetic cooling to microwave ion clocks was earlier proposed by D. J. Wineland and collaborators from National Institute of Standards and Technology, and a preliminary scheme was studied involving the use of 198Hg+ Larson-PRL-1986 and 26Mg+ Bollinger-IEEE-1991 sympathetic cooling 9Be+ in further developments of the Be+ frequency standard in the Penning trap. Microwave ion clocks need to trap a large number of ions stably to improve the signal-to-noise ratio (SNR) during the interrogation of clock signals. Under the sympathetic cooling scheme, Coulomb repulsion of the inner shells of ions makes the stable trapping of large numbers of dual ion systems very challenging experimentally. With the cooling lasers of the coolant ions operating during microwave interrogations, the light shifts caused by these lasers and the fluorescence of the coolant ions must be evaluated carefully.

We had earlier proposed using 24Mg+ to sympathetically cool 113Cd+ and have reported results of our experiment YNZuo-APL-2019 . Compared with that scheme, using 40Ca+ as coolant is more promising because of certain key advantages. First, the mass ratio of 113Cd+ and 40Ca+ is smaller than 113Cd+ and 24Mg+ and therefore increases the cooling efficiency and improves the trapping stability. Second, the reaction rate of 40Ca+ with residual background H2 are much smaller than 24Mg+. The reaction turns the Mg+ into dark ions and is sufficient to limit the cooling efficiency and stability of confinement. Third, the lasers for 40Ca+ are much easier to obtain than those for 24Mg+. All the lasers needed for 40Ca+ cooling can be generated by diode lasers, apart from the ultraviolet laser for 24Mg+ which must be obtained by a fourth-harmonic-generation laser system. The laser system implemented for 40Ca+ has better reliability and is cost effective compared with that of 24Mg+.

In this study, a large number of 113Cd+ ions sympathetically cooled by 40Ca+ and stably confined in a linear Paul trap was experimentally achieved. The number of 113Cd+ ions and 40Ca+ ions reached were 4.2×1054.2\times 10^{5} and 1.7×1051.7\times 10^{5}, respectively, and the confinement time constant reached was 84 hours. The temperature of the Cd+ ions was as low as 90(10)90(10) mK , and the corresponding SODS was estimated to be 1.84(0.2)×1016-1.84(0.2)\times 10^{-16}. The ac Stark shifts caused by the coolant ions were carefully estimated by using an accurate ab initio approach; the magnitude and uncertainty at wavelengths 397 nm and 866 nm were 5.4(0.5)×10175.4(0.5)\times 10^{-17} and 2.0(0.2)×10192.0(0.2)\times 10^{-19}, respectively. The Dick-effect-limited Allan deviation was also deduced as there was no need for an extra cooling procedure; its value was decreased to 1.8×1014/τ1.8\times 10^{-14}/\sqrt{\tau}. These results show that using Ca+ as coolant ions to sympathetically cool Cd+ is very stable and efficient. The main uncertainty of the systematic frequency shifts was significantly reduced to 101610^{-16} level.

II Experiment Scheme

The entire experimental system consists of three parts: the ion trap, the lasers, and the detection system. The ions are trapped in a linear Paul trap using four electrodes. Every electrode is separated into three segments. The middle acts as radio frequency (RF) electrodes for radial confinement, and the ends act as endcap (EC) electrodes for axial confinement. The driving frequency chosen is 2.076 MHz, and the RF voltage varies from 0 V to 500 V, which covers the common stable areas for 113Cd+ and 40Ca+ ions. The EC voltage varies from 0 V to 100 V. To reduce RF heating effects and increase the number of trapped ions, the ratio of R/r0R/r_{0} was optimized and set at 1.1468 Denison-JVST-1971 , where 2R=14.222R=14.22 mm is the outer diameter of the electrode and r0=6.2r_{0}=6.2 mm the radial distance from the axis of the trap to the closest surface of the electrodes. The vacuum of the vacuum chamber is maintained by an ion pump, the background pressure being around 5×10105\times 10^{-10} mBar. Three pairs of Helmholtz coils are used to generate a static magnetic field to split the Zeeman sublevels and compensate for the geomagnetic field.

We chose photoionization instead of electron bombardment ionization to reduce disturbances from stray charges. For the laser setup of the experiment (Fig. 1), the 423-nm (Ca I 4s2S014s4p1P14s^{2}\ {}^{1}S_{0}\rightarrow 4s4p\ ^{1}P_{1}) laser and the 374-nm lasers are used to ionize neutral 40Ca into singly charged ions 40Ca+. The 397-nm (Ca II 4s2S1/24p2P1/24s\ ^{2}S_{1/2}\rightarrow 4p\ ^{2}P_{1/2}) laser and the 866-nm (Ca II 3d2D3/24p2P1/23d\ ^{2}D_{3/2}\rightarrow 4p\ ^{2}P_{1/2}) laser are used for Doppler cooling and repumping the 40Ca+ ions. For 113Cd+, we use the 228-nm (Cd I 5s2S015s5p1P15s^{2}\ {}^{1}S_{0}\rightarrow 5s5p\ ^{1}P_{1}) laser for two-photon ionization of neutral 113Cd. Because of the hyperfine structure of 113Cd+, excited dark states are generated. To improve the cooling and fluorescence detection efficiency, we use a circular polarization laser beam to connect two Zeeman sublevels 5sS1/225s~{}^{2}S_{1/2} (F=1 mF=1) \rightarrow 5pP3/225p~{}^{2}P_{3/2} (F=2 mF=2) to prevent ions from transitioning into dark states 5pP3/225p~{}^{2}P_{3/2} (F=1), and a 15.2-GHz microwave RF signal to repump the ions in dark states 5sS1/225s~{}^{2}S_{1/2} (F=0) back to the cycling transition state. The energy levels of 113Cd+ are shown in Fig. 2.

Refer to caption
Figure 1: Schematic diagram of the experimental setup. M: mirror; Flip M: mirror with flipper; DMLP: long pass dichroic mirror; HWP: half-wave plate; QWP: quarter-wave plate; PBS: polarizing beam splitter; PMT: photomultiplier tube; EMCCD: electron-multiplying charge-coupled device; SG: signal generator; H: horn antenna. A static magnetic field, B, is applied and its direction is parallel to the trap electrodes.
Refer to caption
Figure 2: Energy level scheme of 113Cd+(Not to scale).

For the detection system, we use an electron-multiplying charge-coupled device (EMCCD) to image the structure of the dual-ion system, and a photomultiplier tube (PMT) to determine the number of ion-scattered photons quantitatively. The lens between the EMCCD and PMT are well designed to reduce aberration. The wavelengths used for detection are 397 nm and 214.5 nm for 40Ca+ and 113Cd+, respectively.

III Temperature and Ion-loss Measurements

To apply a sympathetic cooling scheme to a microwave ion clock, two conditions must be met simultaneously: i) a large number of target ions must be stably trapped in the ion trap, and ii) a high sympathetic cooling efficiency must be maintained to keep the target ions at a low temperature.

The measurement of the ion temperature is achieved by measuring Doppler broadening of the laser cooling transition Larson-PRL-1986 ; Bollinger-PRL-1984 . Fig. 3 is a typical measurement result. To reduce cooling and heating effects of the detection laser, the laser power is maintained below 20μ\rm{\mu}W. The fitting curve is a Voigt profile, expressed as origin

F\displaystyle F =\displaystyle= F0+(FLFG)(ν),\displaystyle F_{0}+(F_{L}\ast F_{G})(\nu),
FL(ν)\displaystyle F_{L}(\nu) =\displaystyle= 2AπωL4(ννc)2+ωL2,\displaystyle\frac{2A}{\pi}\frac{\omega_{L}}{4(\nu-\nu_{c})^{2}+\omega_{L}^{2}},
FG(ν)\displaystyle F_{G}(\nu) =\displaystyle= 4ln2πe4ln2ωG2ν2ωG,\displaystyle\sqrt{\frac{4\ln 2}{\pi}}\frac{e^{-\frac{4\ln 2}{\omega^{2}_{G}}*\nu^{2}}}{\omega_{G}}, (1)

where F0F_{0} denotes the offset, ν\nu the laser frequency, νc\nu_{c} the laser center frequency, AA the area, ωL\omega_{L} the Lorentzian width, ωG\omega_{G} the Gaussian width of Doppler broadening, and * means convolution. For 113Cd+, ωL=60.13\omega_{L}=60.13 MHz, which is the natural linewidth of the D2 transition of 113Cd+; the fitted ωG=28.68(1.4)\omega_{G}=28.68(1.4) MHz. The ion temperature is then determined using YNZuo-APL-2019 ; Fritz-book-2006

T=Mc28ln2kB(ωGνc)2,T=\frac{Mc^{2}}{8\ln 2~{}k_{B}}(\frac{\omega_{G}}{\nu_{c}})^{2}, (2)

where MM denotes the mass of 113Cd+, cc the speed of light, and kBk_{B} the Boltzmann constant. The corresponding ion temperature is 93(1.4)93(1.4) mK, which is the upper limit to the temperature of the ions.

Refer to caption
Figure 3: Typical temperature measurement obtained using a Voigt fitting profile.

Although we have optimized the experimental setup for the dual-ion system, we still need to find out the best experimental parameter settings to achieve stable trapping of a large number of ions in the dual-ion system and efficient cooling of target ions. The main heating source stems from RF heating effects, and hence we measured with different RF voltages the temperature of the 113Cd+ ions sympathetically cooled by 40Ca+. From the results (Fig. 4), we see there is a positive correlation between the ion temperature and the RF voltage, signifying RF heating strongly influences ion temperatures. When the RF voltage is above 300 V, we see the ion temperature rising significantly with increasing RF voltage. These hot 40Ca+ ions cannot be maintained in the liquid phase, and the cloud states cannot cool the 113Cd+ ions to very low temperatures. When the RF voltage is below 250 V, the temperature increases with decreasing RF voltage which we attribute to a decrease in the trap depth. The edge of the RF trap potential may contribute additional heating effects through imperfections in the potential wells. When the RF potential is below 200 V, the 113Cd+ ions cannot be stably confined, and the number of ions decreases rapidly.

Refer to caption
Figure 4: RF voltage affects the sympathetic cooling efficiency; the endcap voltage is fixed at 10 V while changing the RF voltage. Each experimental data point is the average of three measurements.

Another experimental parameter is the endcap voltage but has no direct influence on the temperature of ions. Nevertheless, as the endcap voltage increases, the ions are squeezed towards the trap axis, and thus more ions will deviate from the trap center, causing an increase in RF heating effects. We measure the temperature of the sympathetic cooled 113Cd+ ions while changing the endcap voltage (Fig. 5). We find three distinct stages between endcap voltages 30 V–50 V. This includes a sharp rise in 113Cd+ temperature, which may indicate a phase transition of 113Cd+ ions into a cloud state. When the endcap voltage is above 60 V, the 40Ca+ ions cannot be maintained in the liquid phase, and they also cause a sharp increase in temperature of the 113Cd+ ions.

Refer to caption
Figure 5: EC voltage affects the sympathetic cooling efficiency; the RF voltage is fixed at 275 V while changing the EC voltage. Each experimental data point is the average of three measurements.

According to Ref. YNZuo-APL-2019 , there is a complicated relationship between the ion temperature and the RF or EC voltage because a decrease in ion number can strongly influence the ion temperature. In this experiment, ions are more stably confined in the ion trap, and hence the number of ions barely decreases. Without the influence of ion number, the relationship between ion temperature and the RF or EC voltage is more intuitive. The experimental results are simply understood from RF heating effects.

We were able to obtain a set of optimized experimental parameters for the 40Ca+ sympathetic cooling 113Cd+ scheme, the RF and EC voltage being 250 V and 10 V, respectively. At these parameter settings, the temperature of the 113Cd+ ions was measured to be 90(10) mK.

To find the total number of both ion species in the ion trap, we need to know the volume and density of each species. According to Ref. Hornekr-PRL-2001 ; Wineland-PCCSHCIW-1987 , the configurations of the inner and outer layer of ions are cylindrical and ellipsoidal, and the gap between the inner surface of the ellipsoid shell and the outer surface of the inner cylinder is proportional to the square root of the mass ratio. We use these two configurations to fit the dual-ion images taken with the EMCCD [Fig. 6(b)]. From the fitted dimension of the Ca+ and Cd+ ion clouds [Fig. 6(c)], the total ion volume was calculated to be 5.3 mm3 and 34.7 mm3 for 40Ca+ and 113Cd+, respectively. In contrast to results in Ref. YNZuo-APL-2019 , we see from Fig. 6(a) and (b) that, in this experimental scheme, there are nearly no dark ions and the ion signals are much more stable, indicating that using 40Ca+ as coolant to sympathetically cool 113Cd+ is more efficient and stable.

Refer to caption
Figure 6: (a) EMCCD images of the dual-ion system for a 0.3 s exposure time; (b) combined images for Cd+ and Ca+, the Cd+ image being the combination of the seven images from top and bottom, and the Ca+ image being a combination of the three images from left to right (dashed lines represent fitted ion boundaries); (c) fitted dimensions of the Ca+ and Cd+ ion crystals.

For ions trapped at low temperature, their density is usually estimated using the zero-temperature approximation Wineland-PCCSHCIW-1987 ; Hornekr-PRL-2001 ,

n=ε0VRF2MΩ2r04,n=\frac{\varepsilon_{0}V_{RF}^{2}}{M\Omega^{2}r_{0}^{4}}, (3)

where ε0\varepsilon_{0} denotes the permittivity of vacuum, VRFV_{RF} the amplitude of RF voltage, MM the ion mass, Ω\Omega the trap driving frequency, and r0r_{0} the minimum distance from the trap center axis to the surfaces of the electrodes. In this experiment, VRF=250V_{RF}=250V, Ω=2π×2.076\Omega=2\pi\times 2.076 MHz. The number density for 113Cd+ and for 40Ca+ were calculated as nCd=1.2×1013n_{Cd}=1.2\times 10^{13} m-3 and nCa=3.3×1013n_{Ca}=3.3\times 10^{13} m-3, respectively. Therefore, the total number of 40Ca+ and 113Cd+ ions in the ion trap are NCd=4.2×105N_{Cd}=4.2\times 10^{5} and NCa=1.7×105N_{Ca}=1.7\times 10^{5}, respectively.

To analysis the stability of trapping this dual-ion system qualitatively, we measured the loss of 113Cd+ ions from the ion trap. With the RF voltage and EC voltage fixed, and the power and frequency of the lasers stabilized, we assume the PMT counts to be proportional to the ion number. To avoid laser cooling effects during detection, the detection laser is blocked for 10 min after each 20 s measurement [Fig. 7(b)]. The ion-loss measurement results are shown in Fig. 7(a); the counts from background fluorescence have been subtracted. From Fig. 7(a), we see that the PMT counts decrease rapidly at the beginning. This is because when the number of ions is large, more ions are located at positions far from the center of the trap well and cause confinement of these ions at the edge of the potential well that are not very stable. After about 25 min, the trapping of 113Cd+ becomes stable, and the rate of ion loss becomes very slow. The fitted curve is an exponential decay curve, and the time constant is about 84 h. After 3.3 h, the PMT count decreased to 40% (from 18306\rightarrow7021), indicating that there are still 1.7×1051.7\times 10^{5} 113Cd+ ions in the ion trap. This suffices to provide a good SNR for the microwave ion clock. The measurement of the ion number loss shows that under sympathetic cooling this dual-ion system is very stably within the ion trap. Low-temperature stable trapping of 113Cd+ is paramount for further developments to microwave ion clocks.

Refer to caption
Figure 7: (a) Ion-loss measurement results fitted with an exponential decay curve. The fitting was started after 25 min of data taking. (b) Ion-loss measurement methods.

IV Systematic Shifts and Stability Estimation

IV.1 Second-order Doppler Shift

Compared with traditional laser cooling, the sympathetic cooling scheme has many advantages in the application to microwave ion clocks. During pumping and detecting, the large ion clouds are strongly heated by RF heating effects. While the sympathetic cooling scheme is applied, the ions are kept at a low temperature and therefore the uncertainty incurred from SODSs decreases significantly. With the influence of the external field diminished by improving shielding techniques, the SODS has become the fundamental limitation to better accuracy of the microwave ion frequency standard. This highlights the huge potential of applying sympathetic cooling technology in establishing a microwave ion frequency standard.

The estimation of the SODSs for an ion cloud trapped in a Paul trap usually begins with the adoption of a simple model based on the Boltzmann distribution. This simple model is effective at estimating the SODS of ion clouds at high temperature of order of several hundred Kelvin Cutler-APB-1986 ; Prestage-IFCS-1999 . For trapped ions at low temperature, the correlated strength is estimated using coupling parameter Γ=q2/(akBT)\Gamma=q^{2}/(ak_{B}T), where aa denotes the Wigner–Seitz radius 4πna3/3=14\pi na^{3}/3=1 Dubin-RMP-1999 . In our experiment, the temperature of the Cd+ ions is around 90 mK, the density is about 1.2×10131.2\times 10^{13}m-3, and the corresponding coupling parameter is 3333. Under these conditions, the system begins to exhibit local-order characteristics of a fluid Dubin-RMP-1999 , and there are strong correlations between trapped ions. That is, the SODS of trapped ions at low temperature are obviously different from those of ions at high temperatures. The SODSs of this strongly correlated system need further investigation.

Fortunately, we can roughly estimate SODSs using the equipartition theorem Berkeland-JAP-1998 , assuming no micromotion along the axial direction of the Paul trap. The SODSs for the trapped ions are roughly estimated to be

ΔνSODSνclock\displaystyle\frac{\Delta\nu_{\rm{SODS}}}{\nu_{\rm{clock}}} =\displaystyle= 12<vs2>+<vm2>c2\displaystyle-\frac{1}{2}\frac{<v^{2}_{s}>+<v^{2}_{m}>}{c^{2}} (4)
=\displaystyle= 12c2(3kBTM+2kBTM)\displaystyle-\frac{1}{2c^{2}}(\frac{3k_{B}T}{M}+\frac{2k_{B}T}{M})
=\displaystyle= 5kBT2Mc2,\displaystyle-\frac{5k_{B}T}{2Mc^{2}},

where νclock\nu_{\rm{clock}} denotes the ground state hyperfine splitting of 113Cd+; <vs2><v^{2}_{s}> and <vm2><v^{2}_{m}> denote the root mean square of the secular motion and the micromotion velocity, respectively. For ions at temperature 90(10)90(10) mK, the SODS is estimated to be 1.84(0.2)×1016-1.84(0.2)\times 10^{-16}.

IV.2 AC Stark Shift

In the sympathetic cooling scheme, the target ions must always be kept in a low-temperature state through the Coulomb interaction, and hence the lasers of the coolant ion must always be kept on. In the experimental scheme of Ca+ sympathetic cooling of Cd+, the Ca+ cooling laser at wavelength 397 nm and the repumping laser at wavelength 866 nm remain on throughout the experiment. Therefore, during Cd+ hyperfine splitting microwave interrogation, these two wavelengths of the lasers and ion fluorescence inevitably shift the clock transition. For a high-accuracy microwave frequency standard, the ac Stark frequency shift induced by the coolant ions needs to be carefully estimated.

Under the influence of light, each clock level is perturbed. The clock transition frequency is modified by the difference in the perturbed energies,

δνStark(λL)=δα(λL)I,\displaystyle\delta\nu^{\rm{Stark}}(\lambda_{L})=\delta\alpha(\lambda_{L})\cdot I, (5)

where λL\lambda_{L} denotes the perturbed light wavelength, δνStark(λL)\delta\nu^{\rm{Stark}}(\lambda_{L}) the ac Stark shift at wavelength λL\lambda_{L}, δα(λL)\delta\alpha(\lambda_{L}) the difference in ac Stark polarizabilities of the hyperfine states with F=1 and F=0, and II the perturbed light intensity.

The light that shifts the ion energy level consists of two contributions, one from the cooling and repumping lasers of the coolant ions, and the other from the fluorescence of coolant ions. In Doppler cooling, the light intensity of the lasers is typically set to twice the saturation light intensity of the corresponding transition. For the Ca+ 397 nm and 866 nm transitions, the saturation light intensities are 4.663×1024.663\times 10^{-2} W/cm2 and 3.4×1043.4\times 10^{-4} W/cm2 Splatt-phd-2009 , and the corresponding laser intensity IlaserI_{\rm{laser}} are 9.3(0.9)×1029.3(0.9)\times 10^{-2} W/cm2 and 6.8(0.7)×1046.8(0.7)\times 10^{-4} W/cm2 with 10%10\% power fluctuations.

The fluorescence of coolant ions is calculated from the spontaneous emission (SE). The SE scattering rate RR in a laser-cooling process is estimated from Foot-book-2005

R=Γ2Ω2/2δ2+Ω2/2+Γ2/4,R=\frac{\Gamma}{2}\frac{\Omega^{2}/2}{\delta^{2}+\Omega^{2}/2+\Gamma^{2}/4}, (6)

where Γ\Gamma denotes the transition natural linewidth, δ\delta the frequency detuning from resonance, and Ω\Omega the Rabi frequency. The Rabi frequency and saturation intensity are related by Ilaser/Isat=2Ω2/Γ2I_{\rm{laser}}/I_{sat}=2\Omega^{2}/\Gamma^{2}. For the Ca+ cooling (397 nm, Γ=2π×20.67\Gamma=2\pi\times 20.67 MHz, δ=Γ/2\delta=-\Gamma/2) and repumping (866 nm, Γ=2π×1.69\Gamma=2\pi\times 1.69 MHz, δ=0\delta=0) transitions, the scattering rates are 3.2×1073.2\times 10^{7}s-1 and 3.5×1063.5\times 10^{6} s-1, respectively.

The intensity of SE is calculated using I=NRhν/AI=NRh\nu/A, where N=1.7×105N=1.7\times 10^{5} is the number of Ca+ ions, hh the Planck constant, ν\nu the frequency of fluorescence, and AA the luminous area. We assume that the luminous area is equal to the external surface area of Ca+ ion crystal and all the fluorescence influences the clock transition (as an upper limit). We find AA is 31.7 mm2 (see Fig. 6). The SE intensity Ifluo.I_{\rm{\rm{fluo.}}} of the Ca+ cooling and repumping transitions are estimated to be less than 8.6×1068.6\times 10^{-6} W/cm2 and 4.3×1074.3\times 10^{-7} W/cm2, respectively.

The ac Stark polarizabilities δα\delta\alpha at wavelengths 397 nm and 866 nm were analyzed from theory based on second- and third-order perturbation techniques, taking into account the hyperfine interaction, which has been described in detail in Ref. Rosenbusch-PRA-2009 . The calculations were performed using a high-accuracy ab initio approach that included the important many-body and relativistic effects Angstmann-PRA-2006 . The calculation results of the ac Stark shifts are listed in Table 1, along with the relative ac Stark shift δνStark/νclock\delta\nu^{\rm{Stark}}/\nu_{\rm{clock}}.

Table 1: Calculation results of the ac Stark shifts for different wavelengths.
λL\lambda_{L}[nm] 397 866
δα\delta\alpha [Hz/(W/cm2)] 8.75×1068.75\times 10^{-6} 4.54×1064.54\times 10^{-6}
IlaserI_{\rm{laser}} [W/cm2] 9.3(0.9)×1029.3(0.9)\times 10^{-2} 6.8(0.7)×1046.8(0.7)\times 10^{-4}
δνlaserStark\delta\nu^{\rm{Stark}}_{\rm{laser}}[Hz] 8.1(0.8)×1078.1(0.8)\times 10^{-7} 3.1(0.3)×1093.1(0.3)\times 10^{-9}
δνlaserStark/νclock\delta\nu^{\rm{Stark}}_{\rm{laser}}/\nu_{\rm{clock}} 5.4(0.5)×10175.4(0.5)\times 10^{-17} 2.0(0.2)×10192.0(0.2)\times 10^{-19}
Ifluo.I_{\rm{fluo.}} [W/cm2] <8.6×106<8.6\times 10^{-6} <4.3×107<4.3\times 10^{-7}
δνfluo.Stark\delta\nu^{\rm{Stark}}_{\rm{fluo.}}[Hz] <8×1011<8\times 10^{-11} <2×1012<2\times 10^{-12}
δνfluo.Stark/νclock\delta\nu^{\rm{Stark}}_{\rm{fluo.}}/\nu_{\rm{clock}} <6(3)×1021<6(3)\times 10^{-21} <2(1)×1022<2(1)\times 10^{-22}

The results show that the magnitude and uncertainty of the ac Stark shifts were down to 101710^{-17} and 101810^{-18} levels. This is because the two laser frequencies of Ca+ are detuned far from all possible transition frequencies of the Cd+ energy levels. The small shifts indicate that, with the Ca+ sympathetic cooling Cd+ scheme, we no longer need to worry about the influence of the ac Stark shift.

IV.3 Dick Effect

The Dick effect arising from phase noise properties of the local oscillator and the unavoidable dead time, is one of the main limiting factors to short-term frequency stability. The sympathetic cooling scheme offers an effective way to reduce the influence of the Dick effect on stability. The Dick-effect-limited Allan deviation may be expressed as JWZhang-CPL-2015 ; Santarelli-ITUFFC-1998

σyDick(τ)=[1τm=1(gms2+gmc2g02)Syf(m2Tc)]1/2,\sigma^{Dick}_{y}(\tau)=[\frac{1}{\tau}\sum\limits_{m=1}^{\infty}(\frac{g_{ms}^{2}+g_{mc}^{2}}{g_{0}^{2}})S^{f}_{y}(\frac{m}{2T_{c}})]^{-1/2}, (7)

where τ\tau denotes the sampling time, mm the positive integer, TcT_{c} the total time of one measurement cycle, and Syf(m/2Tc)S^{f}_{y}(m/2T_{c}) the one-sided power spectral density of the relative frequency fluctuations of a free running interrogation oscillator at Fourier frequencies m/2Tcm/2T_{c}. The parameters gmsg_{ms}, gmcg_{mc}, and g0g_{0} are defined as

gms\displaystyle g_{ms} =\displaystyle= 12Tc02Tcg(θ)sin(πmθ2Tc)𝑑θ,\displaystyle\frac{1}{2T_{c}}\int_{0}^{2T_{c}}\ g(\theta)sin(\frac{\pi m\theta}{2T_{c}})\,d\theta,
gmc\displaystyle g_{mc} =\displaystyle= 12Tc02Tcg(θ)cos(πmθ2Tc)𝑑θ,\displaystyle\frac{1}{2T_{c}}\int_{0}^{2T_{c}}\ g(\theta)cos(\frac{\pi m\theta}{2T_{c}})\,d\theta,
g0\displaystyle\ g_{0} =\displaystyle= 12Tc02Tcg(θ)𝑑θ,\displaystyle\frac{1}{2T_{c}}\int_{0}^{2T_{c}}\ g(\theta)\,d\theta, (8)

where g(θ)g(\theta) denotes the Ramsey interrogation sensitivity function Santarelli-ITUFFC-1998 .

The time sequences of the laser-cooled and sympathetic-cooled 113Cd+ microwave atomic clocks are presented in Table 2. The cycling transition 5sS1/22(F=1mF=1)5pP3/22(F=2mF=2)5s~{}^{2}S_{1/2}\ (F=1\ m_{F}=1)\rightarrow 5p~{}^{2}P_{3/2}\ (F=2\ m_{F}=2) is used for laser cooling, the transition 5sS1/22(F=1)5pP3/22(F=1)5s~{}^{2}S_{1/2}\ (F=1)\rightarrow 5p~{}^{2}P_{3/2}\ (F=1) is used for pump ions into state 5sS1/22(F=0mF=0)5s~{}^{2}S_{1/2}\ (F=0\ m_{F}=0), and the hyperfine transition 5sS1/22(F=0mF=0)5sS1/22(F=1mF=0)5s~{}^{2}S_{1/2}\ (F=0\ m_{F}=0)\leftrightarrow 5s~{}^{2}S_{1/2}\ (F=1\ m_{F}=0) is the clock transition (see Fig. 2). By using the sympathetic cooling scheme, there is no need for an extra cooling procedure. The cycle time is then reduced from 1830 ms to 830 ms. Using the same local oscillator as mention in JWZhang-CPL-2015 , the Dick-effect-limited Allan deviation was reduced from 3.8×1014/τ3.8\times 10^{-14}/\sqrt{\tau} to 1.8×1014/τ1.8\times 10^{-14}/\sqrt{\tau}, with the frequency stability limit being reduced by half.

Table 2: Time sequences of the laser-cooled and sympathetic-cooled 113Cd+ microwave atomic clocks.
Procedure TLaserT_{\rm{Laser}} (ms) TSymp.T_{\rm{Symp.}} (ms)
Cooling 1000 0
Pumping 50 50
π/2\pi/2 Pulse 15 15
Free evolution 500 500
π/2\pi/2 Pulse 15 15
Detecting 250 250
Dead time 1300 300
Cycle time 1830 830

The fundamental fractional systematic frequency shifts and stability of the laser-cooled KMiao-OL-2015 and sympathetic-cooled Cadmium ion microwave clock systems are compared in Table 3. The total uncertainty associated with these systematic shifts is reduced by three orders of magnitude to the 101710^{-17} level, indicating great potential for developing ultra-high accuracy microwave ion clocks.

Table 3: Fractional systematic shifts and stability of laser-cooled and sympathetic-cooled 113Cd+ microwave atomic clock.
Item Laser-cooled Symp.-cooled
Second-order 1.8(0.3)×1014-1.8(0.3)\times 10^{-14} 1.84(0.2)×1016-1.84(0.2)\times 10^{-16}
Doppler
ac Stark shift 0 5.4(0.5)×10175.4(0.5)\times 10^{-17}
(Laser)
ac Stark shift 0 <6(1)×1021<6(1)\times 10^{-21}
(Fluorescence)
Dick-effect-limited 3.8×1014/τ3.8\times 10^{-14}/\sqrt{\tau} 1.8×1014/τ1.8\times 10^{-14}/\sqrt{\tau}
Allan Deviation

V Conclusions

We achieved long-term low-temperature trapping of a large number of sympathetically cooled 113Cd+ ions using laser-cooled 40Ca+ as coolant. RF trapping was very stable for this Ca+-Cd+ system. After three hours in the trap, up to 10510^{5} Cd+ ions were still confined. The temperature of the 113Cd+ ions was as low as 90 mK, which aided the suppression of the uncertainty associated with the SODS. Using the equipartition theorem, this uncertainty was roughly estimated to be at the 101710^{-17} level. The ac Stark shifts incurred by the Ca+ cooling lasers and fluorescence were carefully estimated. The ac Stark polarizabilities were calculated by high-accuracy ab initio calculations. Because the frequency differences between the two laser frequencies of Ca+ and all possible transitions of Cd+ are large, the magnitude and uncertainty were down to 101710^{-17} and 101810^{-18} levels, and hence can be ignored in these circumstances. The results indicate that using Ca+ sympathetic cooling of Cd+ is expected to be an effective experimental method to improve the accuracy of the Cadmium-ion microwave frequency standard to order 101610^{-16}. In this sympathetic cooling scheme, one cooling procedure is no longer needed. By decreasing dead time, the Dick-effect-limited Allan deviation is also reduced. All of the experimental results and theoretical analysis show that a microwave clock based on sympathetically cooled Cd+ ions holds promise to attain ultrahigh frequency accuracy and stability.

Acknowledgements

We would like to thank Z. Y. Peng and K. Beloy for their helpful discussions and suggestions. This work is supported by the National Key Research and Development Program of China (No. 2016YFA0302100), and the Beijing Natural Science Foundation (1202011). Y. M. Yu acknowledges the National Natural Science Foundation of China (No. 11874064), and the Strategic Priority and Research Program of the Chinese Academy of Sciences (No. XDB21030300). J. Z. Han thanks S. C. Wang for image processing.

References

  • (1) V. A. Dzuba, V. V. Flambaum, M. S. Safronova, S. G. Porsev, T. Pruttivarasin, M. A. Hohensee, and H. Häffner, Strongly enhanced effects of Lorentz symmetry violation in entangled Yb+ ions, Nat. Phys. 12, 465 (2016).
  • (2) P. Wcisło, P. Morzyński, M. Bober, A. Cygan, D. Lisak, R. Ciuryło, and M. Zawada, Experimental constraint on dark matter detection with optical atomic clocks, Nat. Astro. 1, 0009 (2016).
  • (3) M. S. Safronova, D. Budker, D. DeMille, D. F. J. Kimball, A. Derevianko, and C. W. Clark, Search for new physics with atoms and molecules, Rev. Mod. Phys. 90, 025008 (2018).
  • (4) N. Hinkley, J. A. Sherman, N. B. Phillips, M. Schioppo, N. D. Lemke, K. Beloy, M. Pizzocaro, C. W. Oates, and A. D. Ludlow, An Atomic Clock with 101810^{–18} Instability, Science 341, 1215 (2013).
  • (5) T. Bandi, C. Affolderbach, C. E. Calosso and G. Mileti, High-performance laser-pumped rubidium frequency standard for satellite navigation, Elect. Lett. 12, 698 (2011).
  • (6) J. D. Prestage, and G. L. Weaver, Atomic Clocks and Oscillators for Deep-Space Navigation and Radio Science, Proceeding of the IEEE 95, 2235 (2007).
  • (7) R. L Tjoelker, E. A. Burt, S. Chung, R. L. Hamell, J. D. Prestage, B. Tucker, P. Cash, and R. Lutwak, Mercury Atomic Frequency Standards for Space Based Navigation and Timekeeping, 43rd Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting, 293 (2012).
  • (8) S. A. Diddams, J. C. Bergquist, S. R. Jefferts, and C. W. Oates, Standards of Time and Frequency at the Outset of the 21st Century, Science 19, 1318 (2004).
  • (9) S. Weyers, V. Gerginov, M. Kazda, J. Rahm, B. Lipphardt, G. Dobrev, and K. Gibble, Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks, Metrologia 55, 789 (2018)
  • (10) B. M. Jelenković, S. Chung, J. D. Prestage, and L. Maleki, High-resolution microwave-optical double-resonance spectroscopy of hyperfine splitting of trapped 113Cd+ ions, Phys. Rev. A 74, 022505 (2006).
  • (11) K. Miao, J. W. Zhang, X. L. Sun, S. G. Wang, A. M. Zhang, K. Liang, and L. J. Wang, High accuracy measurement of the ground-state hyperfine splitting in a 113Cd+ microwave clock, Opt. Lett 40, 4249 (2015).
  • (12) P. Phoonthong, M. Mizuno, K. Kido, and N. Shiga, Determination of the absolute microwave frequency of lasercooled 171Yb+, Appl. Phys. B 117, 673 (2014).
  • (13) S. Mulholland, H. A. Klein, G. P. Barwood, S. Donnellan, D. Gentle, G. Huang, G. Walsh, P. E. G. Baird, and P. Grill, Laser cooled ytterbium ion microwave frequency standard, Appl. Phys. B 125, 198 (2019).
  • (14) D. J. Berkeland, J. D. Miller, J. C. Bergquist, W. M. Itano, and D. J. Wineland, Laser-Cooled Mercury Ion Frequency Standard, Phys. Rev. Lett. 80, 2089 (1998).
  • (15) E. A. Burt, L. Yi, B. Tucker, R. Hamell, and R. L. Tjoelker, JPL Ultrastable Trapped Ion Atomic Frequency Standards, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 63, 1013 (2016).
  • (16) J. W. Zhang, Z. B. Wang, S. G. Wang, K. Miao, B. Wang, and L. J. Wang, High-resolution laser microwave double-resonance spectroscopy of hyperfine splitting of trapped 113Cd+ and 111Cd+ ions, Phys. Rev. A 86, 022523 (2012).
  • (17) S. G. Wang, J. W. Zhang, K. Miao, Z. B. Wang, and L. J. Wang, High-accuracy measurement of the 113Cd+ ground-state hyperfine splitting at the milli-Hertz level, Opt. Express 21 12434 (2013).
  • (18) J. Z. Han, Y. N. Zuo, J. W. Zhang, and L. J. Wang, Theoretical investigation of the black-body Zeeman shift for microwave atomic clocks, Eur. Phys. J. D 73, 9 (2019).
  • (19) Y. N. Zuo, J. Z. Han, J. W. Zhang, and L. J. Wang, Direct temperature determination of a sympathetically cooled large 113Cd+ ion crystal for a microwave clock, Appl. Phys. Lett. 115, 061103 (2019).
  • (20) J. Z. Han, Y. M. Yu, B. K. Sahoo, J. W. Zhang, and L. J. Wang, Roles of electron correlation effects for the accurate determination of gj factors of low-lying states of 113Cd+ and their applications to atomic clocks, Phys. Rev. A 100, 042508 (2019).
  • (21) J. W. Zhang, K. Miao, and L. J. Wang, Dick Effect in a Microwave Frequency Standard Based on Laser-Cooled 113Cd+ Ions, Chin. Phys. Lett. 32, 010601 (2015).
  • (22) S. M. Brewer, J. S. Chen, A. M. Hankin, E. R. Clements, C. W. Chou, D. J. Wineland, D. B. Hume, and D. R. Leibrandt, 27Al+ Quantum-Logic Clock with a Systematic Uncertainty below 101810^{-18}, Phys. Rev. Lett. 123, 033201 (2019).
  • (23) D. J. Larson, J. C. Bergquist, J. J. Bollinger, Wayne M. Itano, and D. J. Wineland, Sympathetic Cooling of Trapped Ions: A Laser-Cooled Two-Species Nonneutral Ion Plasma, Phys. Rev. Lett. 57, 70 (1986).
  • (24) J. J. Bollinger, D. J. Heinzen, W. M. Itano, S. L. Gilbert, and D. J. Wineland, A 303-MHz Frequency Standard Based on Trapped Be+ Ions, IEEE Transactions on Instrumentation and Measurement 40, 126 (1991).
  • (25) D. R. Denison, Operating parameters of a quadrupole in a grounded cylindrical housing, J. Vac. Sci. Technol. 8, 266 (1971).
  • (26) J. J. Bollinger and D. J. Wineland, Strongly Coupled Nonneutral Ion Plasma, Phys. Rev. Lett. 53, 348 (1984)
  • (27) https://www.originlab.com/doc/Origin-Help/Voigt-FitFunc
  • (28) R. Fritz, Frequency Standards: Basics and Applications (John Wiley and Sons, 2006).
  • (29) D. J. Wineland, Ion Traps for Large Storage Capacity, Proceedings of the Cooling, Condensation and Storage of Hydrogen Cluster Ions Workshop, Menlo Park, California (NTIS, Springfield, VA, 1987).
  • (30) L. Hornekær, N. Kjærgaard, A. M. Thommesen, and M. Drewsen, Structural Properties of Two-Component Coulomb Crystals in Linear Paul Traps, Phys. Rev. Lett. 86, 1994 (2001).
  • (31) L. S. Cutler, C. A. Flory, R. P. Giffard, and M. D. McGuire, Doppler Effects due to Thermal Macromotion of Ions in an rf Quadrupole Trap, Appl. Phys. B 39, 251 (1986).
  • (32) J. D. Prestage, R. L. Tjoelker, and L. Malek, Higher Pole Linear Traps For Atomic Clock Application, Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No. 99CH36313) (1999).
  • (33) D. H. E. Dubin and T. M. O’Neil, Trapped nonneutral plasmas, liquids, and crystals (the thermal equilibrium states), Rev. Mod. Phys. 71, 87 (1999).
  • (34) D. J. Berkeland, J. D. Miller, J. C. Bergquist, W. M. Itano, and D. J. Wineland, Minimization of ion micromotion in a Paul trap, J. Appl. Phys. 83, 5025 (1998).
  • (35) F. E. Splatt, Development and Operation of Miniaturised Ion Traps for Scalable Quantum Computation, PhD thesis, University of Innsbruck, 2009.
  • (36) C. J. Foot, Atomic Physics (Oxford University Press, 2005).
  • (37) P. Rosenbusch, S. Ghezali, V. A. Dzuba, V. V. Flambaum, K. Beloy, and A. Derevianko, ac Stark shift of the Cs microwave atomic clock transitions, Phys. Rev. A 79, 013404 (2009).
  • (38) E. J. Angstmann, V. A. Dzuba, and V. V. Flambaum, Frequency shift of hyperfine transitions due to blackbody radiation, Phys. Rev. A 74, 023405 (2006).
  • (39) G. Santarelli, C. Audoin, A. Makdissi, P. Laurent, G. J. Dick, and A. Clairon, Frequency Stability Degradation of an Oscillator Slaved to a Periodically Interrogated Atomic Resonator, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 45, 887 (1998).