Microbulk Micromegas in non-flammable mixtures of argon and neon at high pressure
Abstract
We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of drift and amplification voltages and pressures from 1 bar to 10 bar for the argon mixture and from 5 bar to 10 bar in the neon mixture, in steps of 1 bar. Maximum gains higher than 1.7 (1.7) in the argon (neon) mixture are measured for all pressures, without the significant decrease with pressure typically observed in other amplification structures. A competitive energy resolution at 22.1 keV, but with a slight degradation with pressure, is observed: from 10.8% at 1 bar to 15.6% FWHM at 10 bar in Ar+1%iC4H10 and from 8.3% at 5 bar to 15.0% FWHM at 10 bar in Ne+2%iC4H10. The experimental setup, procedure and the results will be presented and discussed in detail. The work is motivated by the TREX-DM experiment, that is operating in the Laboratorio Subterráneo de Canfranc with the mentioned mixtures, although the results may be of interest for other applications of time projection chambers at high pressures.
1 Introduction
Charge amplification in gas is the basis for the readout of ionization signals in conventional gas time projection chambers (TPCs). Normally optimized for operation at pressures close to atmospheric, the performance of TPC charge readouts typically decreases with pressure. This is because the effects limiting the normal evolution of the avalanche, leading to streamers and eventually discharges between the electrodes, appear earlier (i.e. at lower gains) in higher gas densities. The precursor of these effects is the production of fluorescence photons in the avalanche, able to initiate secondary avalanches at points separate from the primary avalanche location. The use of quenchers, small amounts of additive gases that are opaque to these photons, is the usual strategy to limit these effects and obtain stable operation, although with an effectiveness that may decrease at higher gas pressures. It is expected that the particular geometry of the amplification structure and the avalanche also play a role, and that different types of readouts show this effect to a different extent.
It is a general observation that gain amplification substantially decreases when going to higher pressures above atmospheric. For example, in [1] the maximum gain of a triple-GEM readout in pure argon is measured to decrease from at 1 bar down to at 5 bar. Among the different types of micro-pattern gas detector (MPGD) technologies, it is known that Micromegas readouts compare favourably in this regard, something that we have tentatively attributed to the higher geometrical confinement of the avalanche [2]. In a Micromegas readout all the amplification takes place in the 50-100 m gap between a micromesh and the anode plane on which it is laid, suspended by insulator pillars. For example, bulk Micromegas operating in Ar+2%iC4H10 have shown a maximum gain drop from 3 at 1.2 bar down to 5 at 10 bar [3].
Microbulk Micromegas [4, 5] are a novel flavour of Micromegas readouts, in which the amplification geometry is obtained out of doubly copper-clad kapton foils, by means of lithography techniques and kapton etching. The resultant readout consists of a thin copper mesh separated from the anode plane by a kapton structure (figure 1) . This technique offers some improvements over conventional Micromegas: the amplification gap is more homogeneous and the mesh is thinner, factors that reduce the avalanche fluctuations and improve the energy resolution, to as low as 11% (10.5%) FWHM at 5.9 keV in argon-(neon-)based mixtures at 1 bar [5] and of 7.3% FWHM at 22.1 keV xenon-trimethylamine (TMA) at 1 bar [6].

There is an important geometrical feature in microbulk detectors, due to the way they are fabricated, by etching the kapton through the holes in the copper mesh. The amplification gap is opened right below each hole in the mesh, forming a cylindrical space in the kapton of diameter slightly larger than the diameter of the corresponding mesh hole. In all the remaining area the kapton is left untouched. This is different than in bulk detectors, in which the insulator forms cylindrical pillars periodically placed along the gap. This means that the avalanche in microbulk detectors is highly confined. Apart from the mesh hole, it is totally surrounded by kapton on the sides and by the anode below. This feature considerably hinders the possibility of photons in the avalanche to spread and could act as a geometrical quenching. This effect has been tentatively invoked to explain the remarkable observation that microbulk detectors present some gain even in pure noble gases [7, 8, 9]. Similarly, this could be suggestive of an improved behaviour at high pressures (i.e. less degradation with pressure), something that has already been experimentally observed in Xe-TMA mixtures [6]. The results presented in this paper qualitatively confirm this statement in Ar and Ne mixtures. We report on a very mild decrease of the maximum gain with pressure (less than a factor of 2 from 1 bar to 10 bar) in both the Ar and Ne mixtures tested (from 5 bar to 10 bar in the latter).
The work here presented has been carried out as part of the TREX-DM experiment, installed in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC). TREX-DM aims at the direct detection of dark matter Weakly Interacting Massive Particles (WIMPs) of particularly low masses (below 10 GeV) [10]. The TREX-DM detector is a high-pressure TPC able to host 0.16 kg of neon target mass at 10 bar (or, alternatively 0.3 kg of argon) and built out of radiopure materials. The core of the experiment are two microbulk Micromegas readout planes with an active area of 24.8 cm2 and with an X-Y strip pattern, the largest single microbulks built so far. Amplification in gas and extreme radiopurity levels show promise to reach the combined low-threshold and low-background needed for a competitive low-mass WIMP sensitivity. The main motivation for the use of microbulk readouts in TREX-DM is their good intrinsic radioactivity, as they are very light structures composed of kapton and copper, two of the materials known to be very radiopure [11]. Recent measurements have set an upper limit for the 238U and 232Th natural chains of tens of nBq/cm2 [12]. TREX-DM is operated in high pressure (currently at 4 bar, but the pressure could be increased up to 10 bar) with Ne+2%iC4H10 and possibly, in a different run, with Ar+1%iC4H10444In this case, underground argon would be employed.. The amount of quencher is set to make the mixtures non-flammable, a fact that facilitates an easier implementation of the experiment underground. The careful characterization of microbulks in these mixtures is therefore needed to assess the performance of the detector. The good behaviour with pressure that is here reported is an additional motivation for the use of such readouts in the experiment.
These results can be of interest to other projects involving high pressure TPCs; an example is the possibility of using a high pressure TPC as a near detector in future long-baseline neutrino experiments. In Sec. 2 and Sec. 3, the experimental setup and the procedure are described. The results in terms of electron transmission, gain and energy resolution are presented in Sec.4, and we finish in Sec. 5 with the conclusions of this work.
2 Experimental setup
The experimental setup used in these measurements (figure 2, left) is a simplified version of the one used in [9, 6]. The main component is a stainless steel vessel555Produced by Telstar., which can reach vacuum values of mbar (and outgassing rates mbar l/sec) and keep gas pressures up to 12 bar. Inside the vessel there is an internal cylindrical chamber (total volume of 2.2 litres, 10 cm height and 16 cm diameter) which can be accessed by a 15 cm diameter DN160CF flange situated on the top. At one side of the vessel, there is a DN40CF flange equipped with four SHV feedthroughs for signal extraction while at another side, there is a DN40CF outlet to pump the chamber and reduce the release of trapped air or other impurities from elements inside the vessel. This pumping system (composed of a turbomolecular pump and two vacuum gauges) is isolated from the chamber by an all-metal valve and another vacuum valve in series. The vessel is also equipped with two DN16CF ports situated at the front (inlet) and at the back (outlet) for the gas flow. At the inlet of the vessel there is a pressure transducer666PTU-F-AC16-33AG by Swagelok., allowing to monitor the vessel’s pressure even when it is isolated from the system via needle valves situated at the ports.


A 3 cm-long field cage (figure 2, right) is placed in the inner chamber. This structure is composed of a 10 cm diameter circular copper cathode and three copper rings. These elements are mechanically fixed together by three PEEK columns and are electrically linked one after the other through 10 M resistors. The cathode has a small hole at its center, where a cylindrical aluminium container with a 109Cd deposition inside is situated. The bottom ring sits on a circular copper plate (figure 3, left) which serves as a support for the microbulk Micromegas readout; the microbulk is fixed in a big hole at the center of the plate, isolated from the vessel by a Teflon rectangular base. The cathode and the anode are electrically connected to the vessel feedthroughs and are independently powered by a CAEN N470A and a CAEN N471 module to a negative and a positive voltage, respectively. The copper plate is electrically connected to the Micromegas mesh, so as to extend the equipotential surface defined by the mesh, and set to the ground. The Micromegas readout is a single, non-segmented anode covering a 2.4 cm diameter area. It is denoted as G50D55P100, as it has an amplification gap of 50 m and an hexagonal mesh hole pattern (figure 3, right), with a hole pitch of 100 m and a hole diameter of 55 m.


An event interacting in the active volume releases electrons, which drift towards the copper plate and the Micromegas readout plane. If these primary electrons are above the active zone of the plane, they will pass through the Micromegas mesh holes towards the higher-field amplification region; then, they will be amplified in the gap and the charge movement will induce signals both at the mesh and the anode. The anode signal is decoupled from the voltage level by a filter, whose constant minimizes the recovery time after a spark to 5 seconds, while the mesh signal is not recorded for the measurements in this work. The anode signal is afterwards processed by a preamplifier777Model 2004 by Canberra., an amplifier888Model 2021 by Canberra. and is subsequently recorded by a Multichannel Analyzer (MCA)999Amptek MCA8000A..
3 Experimental procedure
The experimental procedure starts by pumping the vessel to pressures below mbar and outgassing rates around mbar l/sec. These values are considered sufficient, as no evidence of attachment in the gas has been observed in the readout performance. The all-vacuum valve is then closed and the selected gas from a premixed bottle is injected into the vessel until a desired pressure is reached; the two gas valves are closed and the gas remains static in the vessel during the data-taking, i.e., in sealed-mode operation. After the data-taking, the gas pressure is either increased by 1 bar to make a new measurement or the gas is removed and the vessel is pumped.
The readout has been characterized in terms of electron transmission, gain and energy resolution in Ar+1%iC4H10 for pressures between 1 bar and 10 bar, in steps of 1 bar and was calibrated with a 109Cd source. The measurements in Ne+2%iC4H10 were performed from 5 bar to 10 bar in order to contain the 22 keV energy peak of the source in the small volume of the setup. The calibration spectra generated by the MCA (see figure 4) are characterized by the K-peaks of the source and the fluorescence emissions at 8.048 keV and 8.905 keV from the copper components of the vessel. The mean position and the width of the Kα (at = 22.1 keV) is calculated through an iterative multi-Gaussian fit, previously used in [6], including both the Kα and Kβ (at = 24.9 keV) emission lines, their escape peaks and a linear background. The escape peaks are located at and , where is the absorption energy of the gas, which is 2.974 keV for argon and 0.849 keV for neon.


A wide range of amplification and reduced drift fields has been scanned at each pressure. The anode was varied, in steps of 10 V, from 200 V to 300 V at 1 bar and from 460 V to 580 V at 10 bar in Ar+1%iC4H10; for Ne+2%iC4H10 the corresponding values are from 290 V to 470 V at 5 bar and from 390 V to 560 V at 10 bar. Meanwhile, the drift field was typically varied between 10 V/cm/bar and 300 V/cm/bar, except for pressures near 10 bar, where the field was upper-limited to 200 V/cm/bar; the type of SHV feedthroughs was limiting the maximum voltage applied. These fields translate to drift voltages of 30-900 V at 1 bar and 300-6000 V at 10 bar.
4 Results: electron transmission, gain and energy resolution
The electron transmission is the probability for primary electrons to pass from the conversion volume to the amplification gap through the mesh holes. Its measurement includes two mechanisms that cannot be separated: the electron attachment and recombination in the drift volume, and the so-called transparency of the mesh electrode. In order to measure it, the drift voltage is varied for a fixed anode voltage to obtain the dependence of the electron transmission with the drift-to-amplification field ratio (figure 5, top) and the reduced drift field at each pressure (figure 5, bottom). The fact that the noise level during the measurements was not negligible, of the order of electrons, forced the starting point at detector gains of approximately 100. The specific anode voltages at which each electron transmission curve was taken, as well as the gain and the energy resolution at 200 V/cm/bar are shown in Table 1. As it can be seen, the detector gain was fixed between 0.4 and 1.0 for Ar+1%iC4H10 and between 1.8 and 2.2 for Ne+2%iC4H10. Although this is not an absolute measurement of the electron transmission, the fact that the signal height and the energy resolution (figure 6) become independent of the drift field suggests that the mesh transmission is close to 100% in the plateau range and that the attachment and recombination contributions are negligible, allowing to normalize the maximum value to the signal height. In these measurements, we have normalized all values to the one measured at 200 V/cm/bar; the gain variations along time have also been corrected.
Argon+1%iC4H10 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
P(bar) | 1.0 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 | 7.0 | 8.0 | 9.0 | 10.0 |
Anode(V) | 260 | 300 | 330 | 350 | 400 | 430 | 460 | 490 | 520 | 550 |
G() | 4.76 | 6.43 | 5.74 | 4.16 | 8.64 | 8.07 | 8.34 | 8.84 | 9.39 | 10.00 |
Res. | 10.8 | 11.4 | 12.7 | 13.2 | 13.8 | 14.1 | 14.1 | 14.6 | 14.2 | 15.4 |
Neon+2%iC4H10 | ||||||||||
P(bar) | 1.0 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 | 7.0 | 8.0 | 9.0 | 10.0 |
Anode(V) | - | - | - | - | 380 | 400 | 420 | 440 | 460 | 480 |
G() | - | - | - | - | 1.94 | 1.83 | 2.19 | 2.04 | 2.03 | 1.84 |
Res. | - | - | - | - | 8.8 | 12.3 | 10.7 | 14.2 | 14.9 | 16.6 |




The full transmission plateau is in all cases almost flat for drift fields between 100 V/cm/bar and 300 V/cm/bar, with a maximum variation of 3% for some pressures. At very low drift fields (typically V/cm/bar) the electron transmission is reduced by two effects related to low drift velocities: the charge collection time is longer than the amplifier integration time (4 s) and electron attachment and recombination of primary electrons generated in the drift volume are more important. This drift field threshold is similar to the one reported in [5] and can be explained by the short drift distance in our setup and the combination of a high gas quality and a low outgassing rate. At high fields, the configuration of the field lines makes that some electrons get trapped in the mesh electrode. This effect causes a drop in the mesh transmission and degrades the energy resolution. However, neither an electron transmission drop nor a degradation in energy resolution has been observed in our measurements. According to [5], the full transmission plateau should range for fields up to 150 V/cm for both gases at 1 bar and the detector gain should respectively drop a 20% and 13% when the drift field is increased to 300 V/cm. We have attributed the absence of this effect to the wider mesh holes of our readout, whose diameter is 55 m in comparison to the 35 m of the reference.


After the measurement of the electron transmission, the drift field is set to 200 V/cm/bar, where a full mesh transparency is systematically achieved. The anode voltage is then varied from very low amplification fields, where signals are just at the noise threshold, up to the spark limit, where micro-discharges between the mesh and the anode plane produce a current higher than 300 nA, resulting in a trip of the high-voltage power supply. After a trip, the working voltage is normally recovered within a few seconds but as a fixed criterium, the data-taking is concluded if the trip rate exceeds one every 30 sec. The position of the 22.1 keV peak at the MCA is used to calculate the gain of the Micromegas readout plane, defined as the ratio of the number of electrons after the avalanche () and the number of primary electrons (). To obtain for each peak position, the electronic chain was previously calibrated with a squared-pulse generator and a capacitor. The number of primary electrons is the ratio of the peak energy (22.1 keV) and the mean energy necessary for creating an electron-ion pair in the gas, which is 26.3 eV for argon and 36.4 eV for neon [13]. The contribution due to isobutane has been disregarded because of its low concentration.
The gain curves obtained in Ar+1%iC4H10 for pressures between 1 bar and 10 bar and in Ne+2%iC4H10 between 5 bar and 10 bar are shown in figure 7. The readout shows a maximum attainable gain before the spark limit higher than in the argon mixture and higher than in the neon mixture for all pressures. The uncertainty of this point is of the order of 15%, owing to the 10 V-step in voltage of the data-taking procedure. The maximum gain hardly decreases with pressure: in Ar+1%iC4H10 from at 3 bar down to at 10 bar; while in Ne+2%iC4H10 it drops from at 5 bar down to at 10 bar. This reduction is lower than the one observed in Xe-TMA mixtures for microbulk technology [6], where the maximum gain dropped from at 1 bar to at 10 bar; and in Ar+2%iC4H10 for bulk technology [3], where the maximum gain reduced from at 1.2 bar down to at 10 bar. And it is even lower than the dependence reported in [1] for a triple-GEM gaseous detector in argon, where the maximum gain reduced from at 1 bar down to at 5 bar.


The energy resolution (expressed in FWHM) of the readout plane is obtained from the width of the gaussian fit. Its dependence with the absolute gain is shown in figure 8 for all pressures. The statistical error of the energy resolution, derived from the errors from the gaussian fit parameters, is less than 0.2% FWHM in Ar+1%iC4H10 and 0.3% FWHM in Ne+2%iC4H10 for all gains, except for low gains where it exponentially increases. At each pressure there is a range of gains for which the energy resolution is optimized. At low gains, the energy resolution degrades because the signal becomes comparable to the electronic noise. At high gains, the resolution degrades due to the increase in the gain fluctuations by the UV photons generated in the avalanche [14].


As it is shown in figure 8, the energy resolution at 22.1 keV is degraded with pressure, being 10.8% FWHM at 1 bar and 15.6% FWHM at 10 bar for the argon mixture. For the neon mixture, the energy resolution at 22.1 keV worsens from 8.3% FWHM at 5 bar to 15.0% FWHM at 10 bar. All these values are better than those measured with the bulk readout of TREX-DM in [3], where a degradation from 16% FWHM at 22.1 keV at 1.2 bar to 25% FWHM at 10 bar was observed. Nevertheless, we do not discard that the energy resolution at low pressures may be limited by the low quantity of quencher, as better values have been measured for microbulk technology in [5]: 11.7% and 10.5% FWHM at 5.9 keV in Ar+5%iC4H10 and Ne+5%iC4H10, respectively, which translates to 6.0% and 5.4% FWHM at 22.1 keV if we suppose only an energy dependence.
5 Conclusions and prospects
As part of the commissioning of the TREX-DM experiment, the performance of a non-pixelated microbulk Micromegas readout has been characterized in two non-flammable mixtures: Ar+1%iC4H10 and Ne+2%iC4H10, for pressures between 1 bar (5 bar for Ne) and 10 bar, in steps of 1 bar. The readout shows a maximum attainable gain before the spark limit higher than in argon and in the case of neon higher than for all pressures. The maximum gain decreases with pressure by only a factor 2: in Ar+1%iC4H10 from at 3 bar down to at 10 bar; while in Ne+2%iC4H10 it drops from at 5 bar down to at 10 bar. The energy resolution at 22.1 keV also shows a degradation with pressure: from 10.8% FWHM at 1 bar to 15.6% FWHM at 10 bar in Ar+1%iC4H10; and from 8.3% FWHM at 5 bar to 15.0% FWHM at 10 bar in Ne+2%iC4H10. These results satisfy the criteria set by the TREX-DM experiment for gain and energy resolution, and might be of interest for other applications where high pressure TPC are involved.
Acknowledgments
We thank Rui de Oliveira and his team at the CERN workshop for the microbulk readout planes used in this work, the Servicio General de Apoyo a la Investigación-SAI of the University of Zaragoza for the fabrication of some mechanical components and our IRFU/CEA-Saclay colleagues for their always wise advice. We acknowledge the support from the European Research Council under the European Union’s IDEAS program of the 7th EU Framework Program and under the Horizon 2020 research and innovation programme, grant agreements ERC-2009-StG-240054 (T-REX project) and ERC-2017-AdG-788781 (IAXO+ project) and the Spanish Agencia Estatal de Investigación (AEI) under grants FPA2016-76978-C3-1-P and the coordinated grant PID2019-108122GB. T.D acknowledges the support from the Ramón y Cajal program of the MINECO.
References
- [1] A. Bondar, A. Buzulutskov and L.I. Shekhtman, High pressure operation of the triple-GEM detector in pure Ne, Ar and Xe, Nucl. Instrum. Meth. A A481 (2002) 200 [physics/0103082].
- [2] A. Calcaterra, R. de Sangro, G. Mannocchi, P. Patteri, P. Picchi, M. Piccolo et al., A new concept for streamer quenching in resistive plate chambers, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 565 (2006) 444.
- [3] F.J. Iguaz et al., TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection, Eur. Phys. J. C76 (2016) 529 [1512.01455].
- [4] S. Andriamonje et al., Development and performance of Microbulk Micromegas detectors, JINST 5 (2010) P02001.
- [5] F.J. Iguaz, E. Ferrer-Ribas, A. Giganon and I. Giomataris, Characterization of microbulk detectors in argon- and neon-based mixtures, JINST 7 (2012) P04007 [1201.3012].
- [6] S. Cebrian et al., Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures, JINST 8 (2013) P01012 [1210.3287].
- [7] T. Dafni et al., Energy resolution of alpha particles in a microbulk Micromegas detector at high pressure Argon and Xenon mixtures, Nucl. Instrum. Meth. A608 (2009) 259 [0906.0534].
- [8] A. Tomas et al., Development of Micromegas for neutrinoless double beta decay searches, JINST 4 (2009) P11016.
- [9] S. Cebrian et al., Micromegas readouts for double beta decay searches, JCAP 1010 (2010) 010 [1009.1827].
- [10] A.K. Drukier and S. Nussinov, Towards Detection of Low Mass WIMPs ( GeV/): Mini-Review, Int. J. Mod. Phys. A28 (2013) 1330033.
- [11] S. Cebrian et al., Radiopurity of Micromegas readout planes, Astropart. Phys. 34 (2011) 354 [1005.2022].
- [12] J. Castel et al., Background assessment for the TREX Dark Matter experiment, Eur. Phys. J. C 79 (2019) 782 [1812.04519].
- [13] L. Christophorou, Atomic and Molecular Radiation Physics, John Wiley and Sons, London (1971).
- [14] H. Schindler, S. Biagi and R. Veenhof, Calculation of gas gain fluctuations in uniform fields, Nucl. Instrum. Meth. A 624 (2010) 78.