This paper was converted on www.awesomepapers.org from LaTeX by an anonymous user.
Want to know more? Visit the Converter page.

thanks: Corresponding author

Long-time correlations in single-neutron interferometry data

M. Willsch Institute for Advanced Simulation, Jülich Supercomputing Centre,
Forschungszentrum Jülich, D-52425 Jülich, Germany
RWTH Aachen University, D-52056 Aachen, Germany
   D. Willsch Institute for Advanced Simulation, Jülich Supercomputing Centre,
Forschungszentrum Jülich, D-52425 Jülich, Germany
RWTH Aachen University, D-52056 Aachen, Germany
   F. Jin Institute for Advanced Simulation, Jülich Supercomputing Centre,
Forschungszentrum Jülich, D-52425 Jülich, Germany
   K. Michielsen Institute for Advanced Simulation, Jülich Supercomputing Centre,
Forschungszentrum Jülich, D-52425 Jülich, Germany
RWTH Aachen University, D-52056 Aachen, Germany
   T. Denkmayr, S. Sponar Atominstitut, Vienna University of Technology
A-1020 Vienna, Austria
   Y. Hasegawa Atominstitut, Vienna University of Technology
A-1020 Vienna, Austria
Division of Applied Physics, Hokkaido University
Kita-ku, Sapporo 060-8628, Japan
   H. De Raedt [email protected] Institute for Advanced Simulation, Jülich Supercomputing Centre,
Forschungszentrum Jülich, D-52425 Jülich, Germany
Zernike Institute for Advanced Materials,
University of Groningen, Nijenborgh 4, NL-9747AG Groningen, The Netherlands
Abstract

We present a detailed analysis of the time series of time-stamped neutron counts obtained by single-neutron interferometry. The neutron counting statistics display the usual Poissonian behavior, but the variance of the neutron counts does not. Instead, the variance is found to exhibit a dependence on the phase-shifter setting which can be explained by a probabilistic model that accounts for fluctuations of the phase shift. The time series of the detection events exhibit long-time correlations with amplitudes that also depend on the phase-shifter setting. These correlations appear as damped oscillations with a period of about 2.8s2.8\;\mathrm{s}. By simulation, we show that the correlations of the time differences observed in the experiment can be reproduced by assuming that, for a fixed setting of the phase shifter, the phase shift experienced by the neutrons varies periodically in time with a period of 2.8s2.8\,\mathrm{s}. The same simulations also reproduce the behavior of the variance. Our analysis of the experimental data suggests that time-stamped data of single-particle interference experiments may exhibit transient features that require a description in terms of non-stationary processes, going beyond the standard quantum model of independent random events.

Neutron interferometry, quantum mechanics, foundations of quantum mechanics, computer modeling and simulation

I Introduction

In the description of single-neutron interference experiments it is taken for granted that the detection events can be modeled as independent random variables, meaning that the number of counts registered within a sufficiently large time interval obeys a Poisson distribution Rauch and Werner (2015). Accordingly, the conditional probability of detecting a neutron within a time interval [t,t+τ][t,t+\tau] when a previous one was detected at time tt is given by the exponential distribution P(τ)=exp(τ/Δt)/ΔtP(\tau)=\exp(-\tau/\Delta t)/\Delta t where Δt\Delta t is the average time between two successive detection events at the same detector Rauch and Werner (2015); Grimmet and Stirzaker (2001). The analysis of neutron-counting statistics of interferometry experiments strongly supports the hypothesis that the distribution is Poissonian Rauch and Werner (2015). However, counting statistics only probe the first few moments of the probability distribution and are therefore not well-suited to uncover possible correlations in the time series.

In this paper, we analyze the time series of time-stamped neutron counts obtained by single-neutron interferometry experiments. The main result of this analysis is that the time series of the counts exhibit unexpected long-time correlations with amplitudes that change with the phase shifter setting.

The paper is organized as follows. Section II describes the experiment and the raw experimental data. Results of the statistical analysis of the observed neutron counts and their variances are presented in Sec. III. We show that the neutron counts display the expected sinusoidal behavior but that a more complicated statistical model is required to account for the changes of their variances as a function of the phase shifter setting. In Sec. IV, we analyze the time series of the time-stamped detection events in terms of the correlations of time differences and the type of detection events. We demonstrate that the time series exhibits correlations in the form of damped oscillations with a period of about 2.8 seconds, which is a fairly long time relative to the average time of 1.3 milliseconds between the detection of two successive neutrons. Section V scrutinizes the hypothesis that these correlations are caused by a time-dependent phase shift by performing simulations using two different models. Both models are shown to reproduce the long-time correlations observed experimentally. The paper concludes with the discussion given in Sec. VI.

II Neutron interference experiment

Refer to caption
Figure 1: (color online) Layout of the perfect Si-crystal neutron interferometer Rauch et al. (1974). BS0, …, BS3: beam splitters; phase shifter: aluminum plate; neutrons that are transmitted by BS1 or BS2 leave the interferometer and do not contribute to the interference signal. Detectors count the number of neutrons in the O- and H-beam.

II.1 Description of the experiment

Figure 1 shows the setup of the neutron interference experiment. The three crystal plates, named splitter, mirror and analyzer plate, are assumed to be identical, meaning that they have the same transmissivity and reflectivity Rauch and Werner (2015). The three crystal plates have to be parallel to high accuracy Rauch et al. (1974) and the whole device needs to be protected from vibrations in order to observe interference Kroupa et al. (2000). A monoenergetic neutron beam is split by the splitter plate (BS0). Neutrons refracted by beam splitters BS1 and BS2 (mirror plate) are directed to the analyzer plate (BS3), also acting as a BS, thereby first passing through a rotatable-plate phase shifter (e. g. aluminum plate Rauch and Werner (2015)). Absorption of neutrons by the aluminum plate is assumed to be negligible Rauch and Werner (2015). Minute rotations of the plate about an axis perpendicular to the base plane of the interferometer induce large variations in the phase difference Rauch and Werner (2015); Lemmel and Wagh (2010). Finally, the neutrons are detected by one of the two detectors placed in the so-called O-beam or H-beam. Neutrons which are not refracted by BS1 and BS2 leave the interferometer and do not contribute to the interference signal. Neutron detectors can have a very high detection efficiency of almost 100% Rauch and Werner (2015). A special feature of the experiments about which we report in this paper is that each detected neutron receives a time stamp. The records of the time stamps of the neutrons detected in the O- or H-beam constitute the raw data produced by the experiment. It has already been demonstrated that the time-stamp data can be used to enhance the contrast of the interference fringes and phase resolution Zawisky et al. (1994). At that time, the experiments were performed with the low-flux reactor in Vienna, yielding neutron-counting rates of the order of 1 count per second Zawisky et al. (1994). In contrast, the data analyzed in this paper have been obtained with the reactor in Grenoble, yielding neutron-counting rates of the order of 1000 counts per second (see below).

II.2 Description of the data

The experimental data from 37 repetitions of the experiment were collected on 30 April 2015 at the ILL High-Flux Reactor. The procedure is as follows

  1. 1.

    With n=1,,37n=1,\ldots,37, do steps 2 – 5.

  2. 2.

    Reset the phase shifter to its initial position X=1X=1. This position will be called “setting” of the phase shifter. This setting takes values X=1,,33X=1,\ldots,33.

  3. 3.

    While the phase shifter moves from one setting to the next one, whenever the detector O(H) clicks, write ‘-’ followed by the clock time (= time stamp) to the O(H) stamp file of run number nn.

  4. 4.

    When the phase shifter is in position XX, count neutrons for 10 seconds and whenever the detector O(H) clicks, write ‘+’ followed by the clock time (= time stamp) to the O(H) stamp file of run number nn.

  5. 5.

    Increment XX and change the setting of the phase shifter accordingly. Repeat steps 3 to 5 until XX exceeds 33.

This procedure, which took about 6 hours and 15 minutes, yielded 37 pairs of data files containing time-stamps of 9355720 neutrons detected during the time intervals in which the phase shifter stood still. A very short excerpt from one of these pairs of data files is shown in Table 1.

Table 1: Excerpt of typical time-stamp data, taken from the files ifg_30Apr1806H.stamp and ifg_30Apr1806O.stamp provided to us by the Vienna neutron interferometer group. Column one (two) contains the times at which the detector in the O (H) beam registered the arrival of a neutron. Negative time stamps indicate that the phase shifter is moving from one setting to another one. The fourth to sixth column show the merged time-stamp data tit_{i}, the time differences Δti=titi1\Delta t_{i}=t_{i}-t_{i-1} when tit_{i} and ti1t_{i-1} are both positive, and the encoding of the type of event (xi=1(+1),x_{i}=-1(+1),\ldots indicating the detection of a neutron in the O (H)-beam), respectively. Times are in units of 25μs25\;\mu\mathrm{s}, and the time interval that the phase shifter is not moving from one setting to another is 10 seconds.
O-beam detector H-beam detector Comment Merged times series (tit_{i}) time differences (Δti\Delta t_{i}) Type of event(xix_{i})
-1022655 phase shifter is moving -1022655 1-1
-1115236 -1115236 +1+1
-1124677 -1124677 1-1
-1139548 -1139548 1-1
+1166969 phase shifter stopped moving +1166969 1-1
+1219762 +1219762 52793 +1+1
+1225380 +1225380 5618 +1+1
+1262643 +1262643 37263 +1+1
+1292191 +1292191 29548 +1+1
+1408944 +1408944 116753 +1+1
+1422582 +1422582 13638 +1+1
+1456330 +1456330 33748 +1+1
+1457528 +1457528 1198 +1+1
+1468626 +1468626 11098 1-1
+1559779 +1559779 91153 1-1
+1615907 +1615907 56128 +1+1
+1641410 +1641410 25503 +1+1
+1649128 +1649128 7718 +1+1
+1668761 +1668761 19633 1-1
+1720042 +1720042 51281 1-1
+1779040 +1779040 58998 1-1
+400624979 +400624979 +1+1
+400640127 +400640127 15148 1-1
+400727895 +400727895 87768 +1+1
+400744948 +400744948 17053 +1+1
+400815186 +400815186 70238 1-1
+400864999 +400864999 49813 +1+1
+400947602 +400947602 82603 +1+1
-401110120 phase shifter is moving again -401110120 +1+1

The first step in processing the time-stamp data is to merge the time stamp data of the O- and H-beam detectors in one array and attach a label to each element of this array to keep track of the type of the detection event that the time stamp represents, see Table 1.

On very rare occasions (642 out of the 9355720 neutrons detected during the time intervals in which the phase shifter stands still) we find that there is both an O- and H-event with the same time stamp. We discard such events in the analysis that follows.

III Data analysis

III.1 Fitting the neutron counts to a simple quantum model

In Fig. 2, we present a representative example of the neutron counts in the O- and H-beam as a function of the setting XX of the phase shifter. Our results for the neutron counts match those found in the data files provided to us by the Vienna neutron interferometer group. As the sum of neutrons detected in the O- and H-beam is nearly constant, the sinusoidal dependence of the O- and H-beam counts on XX provides direct evidence for single-neutron interference Rauch et al. (1974); Rauch and Werner (2015).

Refer to caption
Figure 2: (color online) Neutron counts as a function of the setting XX, as obtained from the first pair of data files of the experiment. Open circles (\bigcirc): O-beam; open squares (\Box): H-beam; asterisks (\ast): sum of O- and H-beam counts. Lines through the data points are obtained by fitting to the data as described in the text.
Refer to caption
Figure 3: (color online) The variation of the phase shift offsets χO\chi_{\mathrm{O}} (\bigcirc), χH\chi_{\mathrm{H}} (\Box), χHχO\chi_{\mathrm{H}}-\chi_{\mathrm{O}} (\ast) and the total number of detected neutrons (\bullet) as a function of real time. Lines through the data points are guides to the eye.

A detailed quantum theoretical treatment of the interferometer depicted in Fig. 1 is given in Refs. Rauch and Suda (1974); Rauch and Werner (2015). Assuming that the incident wave satisfies the Bragg condition for scattering by the first crystal plate (BS0), the Laue-type interferometer acts as a two-path interferometer Horne (1986). The simplest description of the crystal plates BS0, BS1, BS2, and BS3 assumes that these plates act as beam splitters for plane waves of neutrons. Then, the unitary matrix that relates the amplitudes of incoming, reflected and transmitted waves is given by U=(trrt)U=\left(\begin{array}[]{cc}\phantom{-}t^{\ast}&r\\ -r^{\ast}&t\end{array}\right) where tt and rr denote the transmission and reflection coefficient, respectively, and the probabilities to observe a particle leaving the interferometer in the O- and H-beam are given by

pO\displaystyle p_{\mathrm{O}} =\displaystyle= 2R2T(1+cosχ),\displaystyle 2R^{2}T\left(1+\cos\chi\right), (1)
pH\displaystyle p_{\mathrm{H}} =\displaystyle= R(T2+R2)(12RTT2+R2cosχ),\displaystyle R(T^{2}+R^{2})\left(1-\frac{2RT}{T^{2}+R^{2}}\cos\chi\right), (2)

where χ\chi is the relative phase shift between the two different paths that the neutrons can take, R=|r|2R=|r|^{2} and T=|t|2=1RT=|t|^{2}=1-R. Note that pOp_{\mathrm{O}} and pHp_{\mathrm{H}} do not depend on the imaginary part of tt or rr, leaving only one free model parameter (e.g. RR). In the case of a 50-50 beam splitter (T=R=1/2T=R=1/2), Eqs. (1) and (2) reduce to the familiar expressions pO=(1/2)cos2χ/2p_{\mathrm{O}}=(1/2)\cos^{2}\chi/2 and pH=(1/2)sin2χ/2p_{\mathrm{H}}=(1/2)\sin^{2}\chi/2, respectively. The extra factor one-half is due to the fact that if T=R=1/2T=R=1/2, one half of all incoming neutrons, that is the neutrons that are transmitted by BS1 or BS2 (see Fig. 1), leave the interferometer without being counted.

The expression in Eq. (1) shows that the normalized (to the maximum value) O-beam intensity does not depend on the value of the reflectivity RR. Furthermore, Eq. (1) implies that the visibility of the O-beam is given by

VO\displaystyle V_{\mathrm{O}} \displaystyle\equiv maxχpOminχpOmaxχpO+minχpO=1.\displaystyle\frac{\max_{\chi}p_{\mathrm{O}}-\min_{\chi}p_{\mathrm{O}}}{\max_{\chi}p_{\mathrm{O}}+\min_{\chi}p_{\mathrm{O}}}=1. (3)

Figure 2 clearly shows that the visibility of the O-beam interference signal is not equal to one. Therefore, instead of using Eqs. (1) and (2), we take as a model for the neutron counts Rauch and Werner (2015)

NO\displaystyle N_{\mathrm{O}} =\displaystyle= AO[1+BOcos(ΩOX+χO)],\displaystyle A_{\mathrm{O}}\left[1+B_{\mathrm{O}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}})\right], (4)
NH\displaystyle N_{\mathrm{H}} =\displaystyle= AH[1+BHcos(ΩHX+χH)].\displaystyle A_{\mathrm{H}}\left[1+B_{\mathrm{H}}\cos(\Omega_{\mathrm{H}}X+\chi_{\mathrm{H}})\right]. (5)

Fitting Eqs. (4) and (5) to the data shown in Fig. 2 yields AO2781A_{\mathrm{O}}\approx 2781, AH4951A_{\mathrm{H}}\approx 4951, BO0.74B_{\mathrm{O}}\approx 0.74, BH0.42B_{\mathrm{H}}\approx 0.42, ΩO0.60\Omega_{\mathrm{O}}\approx 0.60, ΩH0.60\Omega_{\mathrm{H}}\approx 0.60, χO2.75\chi_{\mathrm{O}}\approx-2.75, and χH0.37\chi_{\mathrm{H}}\approx 0.37.

For the statistical analysis of the time series to be presented later, it is important to know over which time span the counts and phases are fairly constant as phase drifts due to thermal fluctuations are not unusual in such experiments Geppert et al. (2014). In Fig. 3, we plot the phase shift offsets χO\chi_{\mathrm{O}} (\Box), χH\chi_{\mathrm{H}} (\bigcirc), χHχO\chi_{\mathrm{H}}-\chi_{\mathrm{O}} (\ast) and the total number of detected neutrons as a function of the elapsed time. Note that χHχOπ\chi_{\mathrm{H}}-\chi_{\mathrm{O}}\approx\pi implies that the maxima in the H-counts are shifted by 180180^{\circ} relative to those of the O-counts, in agreement with the quantum theoretical prediction given by Eqs. (1) and (2). During the first 6 hours of collecting data, the counts and phases are fairly constant.

Refer to caption
Figure 4: (color online) Neutron counts NON_{\mathrm{O}} and NHN_{\mathrm{H}} as a function of the setting XX, averaged over the 37 pairs of data files. Open circles (\bigcirc): O-beam; open squares (\Box): H-beam; asterisks (\ast): sum of O- and H-beam counts. Lines through the data points are obtained by fitting to the data as described in the text. The standard deviations, indicated by the error bars, are of the size of the markers.

Fitting the parameters that appear in Eqs. (4) and (5) to the counts averaged over all experiments, we obtain AO2780A_{\mathrm{O}}\approx 2780, AH4950A_{\mathrm{H}}\approx 4950, BO0.74B_{\mathrm{O}}\approx 0.74, BH0.42B_{\mathrm{H}}\approx 0.42, ΩO0.60\Omega_{\mathrm{O}}\approx 0.60, ΩH0.60\Omega_{\mathrm{H}}\approx 0.60, χO2.71\chi_{\mathrm{O}}\approx-2.71, and χH0.43\chi_{\mathrm{H}}\approx 0.43, yielding χ0.60X\chi\approx 0.60X. In Fig. 4 we present the data of counts averaged over all experiments together with the results of the fitting procedure.

From Eqs. (1) and (2) and the values of the mean (over all settings) of the O- and H-beam counts AOA_{\mathrm{O}} and AHA_{\mathrm{H}}, we can estimate the reflectivity RR by solving the quadratic equation

α=AHAO=02π𝑑χR(T2+R2)[1(2RT/(T2+R2))cosχ]02π𝑑χ 2R2T[1+cosχ]=(1R)2+R22R(1R),\displaystyle\alpha=\frac{A_{\mathrm{H}}}{A_{\mathrm{O}}}=\frac{\int_{0}^{2\pi}d\chi\;R(T^{2}+R^{2})\left[1-({2RT}/{(T^{2}+R^{2})})\cos\chi\right]}{\int_{0}^{2\pi}d\chi\;2R^{2}T\left[1+\cos\chi\right]}=\frac{(1-R)^{2}+R^{2}}{2R(1-R)}, (6)

and we find that α1.78\alpha\approx 1.78 and R=(1+(α1)/(α+1))/20.76R=(1+\sqrt{(\alpha-1)/(\alpha+1)})/2\approx 0.76 (or 0.240.24 if we take the solution with the minus sign). According to the quantum theoretical model, the relative amplitude of the H-beam fringes should then be 2RT/(T2+R2)=1/α0.56{2RT}/{(T^{2}+R^{2})}=1/\alpha\approx 0.56, which is not in good quantitative agreement with the amplitude BH0.42B_{\mathrm{H}}\approx 0.42 extracted from the experimental data. In view of the quantum model of crystal plates BS0, …, BS3 that we used to estimate RR, this quantitative disagreement only calls for a more comprehensive model of the Bragg scattering at the crystal plates Rauch and Werner (2015). At any rate, Eqs. (4) and (5) with the values of the parameters given above describe the experimental data very well. The relative frequencies to detect a neutron in the O- or H-beam are, to a very good approximation, given by

PO\displaystyle P_{\mathrm{O}} =\displaystyle= AOAO+AH[1+BOcos(ΩOX+χO)],\displaystyle\frac{A_{\mathrm{O}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\bigg{[}1+B_{\mathrm{O}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}})\bigg{]}, (7)
PH\displaystyle P_{\mathrm{H}} =\displaystyle= AHAO+AH[1BOAOAHcos(ΩOX+χO)],\displaystyle\frac{A_{\mathrm{H}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\left[1-\frac{B_{\mathrm{O}}A_{\mathrm{O}}}{A_{\mathrm{H}}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}})\right], (8)

where we used the empirical finding that AOBOAHBHA_{\mathrm{O}}B_{\mathrm{O}}\approx A_{\mathrm{H}}B_{\mathrm{H}} and that χHχO+π\chi_{\mathrm{H}}\approx\chi_{\mathrm{O}}+\pi.

III.2 Fitting the standard deviation

In Fig. 4, the error bars are hardly discernible but as shown in Fig. 5, the standard deviations of the counts as a function of XX explicitly display a nontrivial periodic dependence on XX. The standard deviation is at a minimum for those settings at which the corresponding counts reach a maximum or a minimum.

We make contact with a probabilistic model, in this case quantum theory, by assigning the values of the relative frequencies given by Eqs. (7) and (8) to the probabilities of the corresponding events. Quantum theory postulates that the detected events (represented by x=+1(1)x=+1(-1) for an O (H) detection event, respectively) are statistically independent random variables. Therefore, for each of the 37 repetitions of the experiment, we expect that the probability to observe NON_{\mathrm{O}} counts is given by the binomial distribution Barlow (1989)

p(NO)\displaystyle p(N_{\mathrm{O}}) =\displaystyle= N!NO!(NNO)!PONO(1PO)NNO,\displaystyle\frac{N!}{N_{\mathrm{O}}!(N-N_{\mathrm{O}})!}P_{\mathrm{O}}^{N_{\mathrm{O}}}(1-P_{\mathrm{O}})^{N-N_{\mathrm{O}}}, (9)

where N=AO+AHN=A_{\mathrm{O}}+A_{\mathrm{H}} is the total number of events observed in one run. From Eq. (9), it follows that for the same run, the averages of NON_{\mathrm{O}} and NO2N^{2}_{\mathrm{O}} are given by

NO=NPO,NO2=N2PO2+NPO(1PO),\displaystyle\langle N_{\mathrm{O}}\rangle=NP_{\mathrm{O}}\quad,\quad\langle N^{2}_{\mathrm{O}}\rangle=N^{2}P^{2}_{\mathrm{O}}+NP_{\mathrm{O}}(1-P_{\mathrm{O}}), (10)

respectively.

Plotting the standard deviations (NO2NO2)1/2=(\langle N^{2}_{\mathrm{O}}\rangle-\langle N_{\mathrm{O}}\rangle^{2})^{1/2}= (NH2NH2)1/2=(NPOPH)1/2(\langle N^{2}_{\mathrm{H}}\rangle-\langle N_{\mathrm{H}}\rangle^{2})^{1/2}=(NP_{\mathrm{O}}P_{\mathrm{H}})^{1/2} obtained by using the values of the parameters determined by fitting to the experimentally observed counts yields curves that are very different from those of the standard deviations computed from the data obtained by the 37 repetitions of the experiment (see below). Therefore, the observed data cannot be described by a simple Bernoulli process. Of course, this process does not capture all the physical influences that affect the O- and H-beam counts, such as fluctuations in the total neutron count N=AO+AHN=A_{\mathrm{O}}+A_{\mathrm{H}} from run to run (see the asterisks in Fig. 4) and fluctuations ϵ\epsilon of the phase shift at a fixed setting XX. The internal phase of the interferometer varies by about 0.0349 due to reflection effects (Pendellösung structure) of the interferometer crystal Rauch and Werner (2015).

We incorporate the effect of the two types of fluctuations into the probabilistic model by assuming that they are described by the probability distribution p(N)p(N) and p(ϵ)p(\epsilon), respectively, and that the individual O- and H-detection events are described by Bernoulli processes with success probabilities

P^O(X,ϵ)\displaystyle\widehat{P}_{\mathrm{O}}(X,\epsilon) =\displaystyle= AOAO+AH[1+BOcos(ΩOX+χO+ϵ)],\displaystyle\frac{A_{\mathrm{O}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\bigg{[}1+B_{\mathrm{O}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}}+\epsilon)\bigg{]}, (11)
P^H(X,ϵ)\displaystyle\widehat{P}_{\mathrm{H}}(X,\epsilon) =\displaystyle= AHAO+AH[1BOAOAHcos(ΩOX+χO+ϵ)].\displaystyle\frac{A_{\mathrm{H}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\left[1-\frac{B_{\mathrm{O}}A_{\mathrm{O}}}{A_{\mathrm{H}}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}}+\epsilon)\right]. (12)

Temporarily writing P^=P^(ϵ)=P^O(X,ϵ)\widehat{P}=\widehat{P}(\epsilon)=\widehat{P}_{\mathrm{O}}(X,\epsilon), we have for the average O-count

NO\displaystyle\langle N_{\mathrm{O}}\rangle =\displaystyle= NNP^(ϵ)p(N)p(ϵ)𝑑ϵ=NNP^ϵ,\displaystyle\sum_{N}\int N\widehat{P}(\epsilon)p(N)p(\epsilon)\;d\epsilon=\langle N\rangle_{N}\langle\widehat{P}\rangle_{\epsilon}, (13)

where .N\langle.\rangle_{N} and .ϵ\langle.\rangle_{\epsilon} denote the expectation value with respect to the probability distribution p(N)p(N) and p(ϵ)p(\epsilon), respectively. For the average of the O-counts squared we have

NO2\displaystyle\langle N^{2}_{\mathrm{O}}\rangle =\displaystyle= N[N(N1)P^2(ϵ)+NP^(ϵ)]p(ϵ)p(N)𝑑ϵ=N(N1)NP^2ϵ+NNP^ϵ\displaystyle\sum_{N}\int\left[N(N-1)\widehat{P}^{2}(\epsilon)+N\widehat{P}(\epsilon)\right]p(\epsilon)p(N)\;d\epsilon=\langle N(N-1)\rangle_{N}\langle\widehat{P}^{2}\rangle_{\epsilon}+\langle N\rangle_{N}\langle\widehat{P}\rangle_{\epsilon} (14)
=\displaystyle= (N2NNN2)(P^2ϵP^ϵ2)+NN(NN1)(P^2ϵP^ϵ2)\displaystyle(\langle N^{2}\rangle_{N}^{\phantom{2}}-\langle N\rangle_{N}^{2})(\langle\widehat{P}^{2}\rangle_{\epsilon}^{\phantom{2}}-\langle\widehat{P}\rangle_{\epsilon}^{2})+\langle N\rangle_{N}^{\phantom{2}}(\langle N\rangle_{N}^{\phantom{2}}-1)(\langle\widehat{P}^{2}\rangle_{\epsilon}^{\phantom{2}}-\langle\widehat{P}\rangle_{\epsilon}^{2})
+P^ϵ2(N2NNN2)+NNP^ϵ(1P^ϵ)+NN2P^ϵ2,\displaystyle+\langle\widehat{P}\rangle_{\epsilon}^{2}(\langle N^{2}\rangle_{N}^{\phantom{2}}-\langle N\rangle_{N}^{2})+\langle N\rangle_{N}^{\phantom{2}}\langle\widehat{P}\rangle_{\epsilon}(1-\langle\widehat{P}\rangle_{\epsilon}^{\phantom{2}})+\langle N\rangle_{N}^{2}\langle\widehat{P}\rangle_{\epsilon}^{2},

such that the variance on the O-counts is given by

NO2NO2\displaystyle\langle N^{2}_{\mathrm{O}}\rangle-\langle N_{\mathrm{O}}^{\phantom{2}}\rangle^{2} =\displaystyle= σN2σP^2+P^ϵ2σN2+NN(NN1)σP^2+NNP^ϵ(1P^ϵ),\displaystyle\sigma_{N}^{2}\sigma_{\widehat{P}}^{2}+\langle\widehat{P}\rangle_{\epsilon}^{2}\sigma_{N}^{2}+\langle N\rangle_{N}^{\phantom{2}}(\langle N\rangle_{N}^{\phantom{2}}-1)\sigma_{\widehat{P}}^{2}+\langle N\rangle_{N}\langle\widehat{P}\rangle_{\epsilon}(1-\langle\widehat{P}\rangle_{\epsilon}), (15)

where σN2=N2NNN2\sigma_{N}^{2}=\langle N^{2}\rangle_{N}^{\phantom{2}}-\langle N\rangle_{N}^{2} and σP^2=P^2ϵP^ϵ2\sigma_{\widehat{P}}^{2}=\langle\widehat{P}^{2}\rangle_{\epsilon}^{\phantom{2}}-\langle\widehat{P}\rangle_{\epsilon}^{2}. The variance on the H-count is given by Eq. (15) with the subscript O replaced by H and P^\widehat{P} replaced by P^=P^(ϵ)=P^H(X,ϵ)\widehat{P}=\widehat{P}(\epsilon)=\widehat{P}_{\mathrm{H}}(X,\epsilon).

Assuming that there are no fluctuations in the phase (σP^2=0\sigma_{\widehat{P}}^{2}=0) and that the total number of counts varies from run to run in a way described by a Poisson process (σN2=NN\sigma_{N}^{2}=\langle N\rangle_{N}), Eq. (15) reduces to NO2NO2=NNPO\langle N^{2}_{\mathrm{O}}\rangle-\langle N_{\mathrm{O}}^{\phantom{2}}\rangle^{2}=\langle N\rangle_{N}P_{\mathrm{O}}, meaning that the standard deviation on the counts is, up to a factor, given by the square root of the counts Rauch and Werner (2015), in blatant contradiction with the data analyzed in this paper. It other words, the assumption that there are no fluctuations in the phase may not be correct. As a matter of fact, the estimated phase fluctuates from run to run, see Fig. 3 and also Fig. 2.10 in Ref. Rauch and Werner (2015). Whether or not these long-term phase fluctuations have a noticeable effect on the standard deviation depends on the relative weight of the σP^2\sigma_{\widehat{P}}^{2} terms in Eq. (15). Apparently, for the data analyzed in this paper, the contribution of the σP^2\sigma_{\widehat{P}}^{2} terms to the standard deviation is significant, see Fig. 5.

As a simple model for the random fluctuations in the phase shift for a fixed setting XX, we take a uniform distribution over a small interval [ϵ0,ϵ0][-\epsilon_{0},\epsilon_{0}]. Then, we find that

P^Oϵ\displaystyle\langle\widehat{P}_{\mathrm{O}}\rangle_{\epsilon} =\displaystyle= AOAO+AH[1+(1ϵ026)BOcos(ΩOX+χO)]+𝒪(ϵ03),\displaystyle\frac{A_{\mathrm{O}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\bigg{[}1+(1-\frac{\epsilon_{0}^{2}}{6})B_{\mathrm{O}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}})\bigg{]}+{\cal O}(\epsilon_{0}^{3}),
P^Hϵ\displaystyle\langle\widehat{P}_{\mathrm{H}}\rangle_{\epsilon} =\displaystyle= AHAO+AH[1(1ϵ026)BOAOAHcos(ΩOX+χO)]+𝒪(ϵ03),\displaystyle\frac{A_{\mathrm{H}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\left[1-(1-\frac{\epsilon_{0}^{2}}{6})\frac{B_{\mathrm{O}}A_{\mathrm{O}}}{A_{\mathrm{H}}}\cos(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}})\right]+{\cal O}(\epsilon_{0}^{3}),
σP^2\displaystyle\sigma_{\widehat{P}}^{2} =\displaystyle= ϵ023(AOBOAO+BO)sin2(ΩOX+χO)+𝒪(ϵ03),\displaystyle\frac{\epsilon_{0}^{2}}{3}\left(\frac{A_{\mathrm{O}}B_{\mathrm{O}}}{A_{\mathrm{O}}+B_{\mathrm{O}}}\right)\sin^{2}(\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}})+{\cal O}(\epsilon_{0}^{3}), (16)

where the latter holds for both the O- and H-counts.

Refer to caption
Refer to caption
Figure 5: (color online) Standard deviation of the neutron counts as a function of the setting XX, as obtained from the 37 pairs of data files. (a) \bigcirc: experimental O-beam data. Solid line: (NO2NO2)1/2(\langle N^{2}_{\mathrm{O}}\rangle-\langle N_{\mathrm{O}}\rangle^{2})^{1/2} as obtained from the theoretical model Eqs. (15) and (16) accounting for fluctuations of the phase shift. Dashed line: (NO2NO2)1/2=(NPOPH)1/2(\langle N^{2}_{\mathrm{O}}\rangle-\langle N_{\mathrm{O}}\rangle^{2})^{1/2}=\left(NP_{\mathrm{O}}P_{\mathrm{H}}\right)^{1/2} as obtained from the standard model Eq. (10), using the value of POP_{\mathrm{O}} obtained from the experimental O-beam counts. (b) Same as (a) but for the H-beam instead of the O-beam data.

The numerical results for (NO2NO2)1/2(\langle N^{2}_{\mathrm{O}}\rangle-\langle N_{\mathrm{O}}^{\phantom{2}}\rangle^{2})^{1/2} are shown in Fig. 5 as the solid line. The standard deviation of the neutron counts in the H-beam and (NH2NH2)1/2(\langle N^{2}_{\mathrm{H}}\rangle-\langle N_{\mathrm{H}}^{\phantom{2}}\rangle^{2})^{1/2} show similar agreement (not shown). The values of the parameters used are AO=2745A_{\mathrm{O}}=2745, AH=4916A_{\mathrm{H}}=4916, BO=0.73B_{\mathrm{O}}=0.73, BH=0.42B_{\mathrm{H}}=0.42, ΩO=0.60\Omega_{\mathrm{O}}=0.60, χ0=2.7\chi_{0}=-2.7, and ϵ0=0.13\epsilon_{0}=0.13. This is a slightly different set of parameters than the one used to draw the lines in Fig. 4 but as the changes in the new plot of the counts are not visible, we do not show it.

Refer to caption
Figure 6: (color online) The correlation CO(Δt)C_{\mathrm{O}}(\Delta t) of the time-differences between the O-beam detection events for different phase shifter settings XX as a function of the time difference Δt\Delta t, computed from the 37 pairs of data files. Fitting the function f(Δt)=aexp(bΔt)cos(2πΔt/𝒯)f(\Delta t)=a\exp(-b\Delta t)\cos(2\pi\Delta t/{\cal T}) to the data yields 𝒯2.8s{\cal T}\approx 2.8\;\mathrm{s} for the period of the oscillations in the correlation CO(Δt)C_{\mathrm{O}}(\Delta t).
Refer to caption
Figure 7: (color online) The correlation CE(Δt)C_{\mathrm{E}}(\Delta t) of the time-differences of the O-beam (a, E=O), H-beam (b, E=H) and O-beam or H-beam (c, E=OH) detection events for the same phase shifter setting X=12X=12 as a function of the time difference Δt\Delta t, computed from the 37 pairs of data files.
Refer to caption
Figure 8: (color online) The maximum amplitudes of the oscillations in CO(Δt)C_{\mathrm{O}}(\Delta t) (\bigcirc) and CH(Δt)C_{\mathrm{H}}(\Delta t) (\Box), computed from the experimental data, as a function of the phase shifter setting XX. Lines through the data points are guides to the eye.

IV Analysis of the time series

IV.1 Correlation of the time differences

We denote the nnth moment of the time difference of two successive neutron detection events in either the O- or H-beam by

(Δt)n\displaystyle\langle(\Delta t)^{n}\rangle \displaystyle\equiv 1Mi=1M(Δti(E))n,\displaystyle\frac{1}{M}\sum_{i=1}^{M}\left(\Delta t_{i}^{\mathrm{(E)}}\right)^{n}, (17)

where we introduce the subscript E{O,H,OH}\mathrm{E}\in\{\mathrm{O},\mathrm{H},\mathrm{OH}\} to indicate that we consider only the O-, H- or (O or H)-beam detection events, respectively. From the time-stamp data, we find for the average time Δt1.3ms\langle\Delta t\rangle\approx 1.3\;\mathrm{ms}, which is much larger than the time it takes for a neutron to traverse the interferometer (which is of the order of 0.1ms0.1\mathrm{ms} Rauch and Werner (2015)). Therefore, it is very reasonable to assume that at any time, there is at most one neutron in the region of space occupied by the interferometer Rauch and Werner (2015). In other words, if the experiment yields an interference signal, this signal is built up by single neutrons that travel though the interferometer one-by-one Rauch et al. (1974); Rauch and Werner (2015). If the distribution of the time differences is exponential (as in the case of a Poisson process), the averages of the first three moments of the time differences are related by Δt=((Δt)2/2)1/2=((Δt)3/6)1/3\langle\Delta t\rangle=(\langle(\Delta t)^{2}\rangle/2)^{1/2}=(\langle(\Delta t)^{3}\rangle/6)^{1/3}. Using the experimental data, we find that within 1%, Δt((Δt)2/2)1/2((Δt)3/6)1/3\langle\Delta t\rangle\approx(\langle(\Delta t)^{2}\rangle/2)^{1/2}\approx(\langle(\Delta t)^{3}\rangle/6)^{1/3}, suggesting that Δti(OH)\Delta t_{i}^{(\mathrm{OH})} may indeed be described by an exponential distribution. Plotting (data not shown) the distribution of the frequencies with which the Δti(E)\Delta t_{i}^{(\mathrm{E})}’s (for E{O,H,OH}\mathrm{E}\in\{\mathrm{O},\mathrm{H},\mathrm{OH}\}) occur indeed shows the exponential dependence, in concert with the finding that the detection times can be described by a Poisson process Rauch and Werner (2015).

A key feature of quantum theory and also of a Poisson process is that the events are independent Grimmet and Stirzaker (2001). We can test the hypothesis that the detection events are independent by studying the time series of the Δti\Delta t_{i}’s in more detail.

For each of the nn time-stamp files and for each setting XX, we calculate the averages

Δt(E,k)\displaystyle\langle\Delta t^{(\mathrm{E},k)}\rangle \displaystyle\equiv 1M(E)ki=1M(E)kΔti+k(E),\displaystyle\frac{1}{M^{(\mathrm{E})}-k}\sum_{i=1}^{M^{(\mathrm{E})}-k}\Delta t^{(\mathrm{E})}_{i+k}\;,
(Δt(E,k))2\displaystyle\langle\left(\Delta t^{(\mathrm{E},k)}\right)^{2}\rangle \displaystyle\equiv 1M(E)ki=1M(E)k(Δti+k(E))2,\displaystyle\frac{1}{M^{(\mathrm{E})}-k}\sum_{i=1}^{M^{(\mathrm{E})}-k}\left(\Delta t^{(\mathrm{E})}_{i+k}\right)^{2}\;,
Δt(E,0)Δt(E,k)\displaystyle\langle\Delta t^{(\mathrm{E},0)}\Delta t^{(\mathrm{E},k)}\rangle \displaystyle\equiv 1M(E)ki=1M(E)kΔti(E)Δti+k(E),\displaystyle\frac{1}{M^{(\mathrm{E})}-k}\sum_{i=1}^{M^{(\mathrm{E})}-k}\Delta t^{(\mathrm{E})}_{i}\Delta t^{(\mathrm{E})}_{i+k}\;, (18)

where M(E)M^{(\mathrm{E})} is the number of time differences per setting XX and k=0,1,,ME1k=0,1,\ldots,M_{\mathrm{E}}-1. We use these averages to compute the correlation Barlow (1989)

CE(Δt)=CE(kΔt)Δt(E,0)Δt(E,k)Δt(E,0)Δt(E,k)[(Δt(E,0))2Δt(E,0)2][(Δt(E,k))2Δt(E,k)2],\displaystyle C_{\mathrm{E}}(\Delta t)=C_{\mathrm{E}}(k\langle\Delta t\rangle)\equiv\frac{\langle\Delta t^{(\mathrm{E},0)}\Delta t^{(\mathrm{E},k)}\rangle-\langle\Delta t^{(\mathrm{E},0)}\rangle\langle\Delta t^{(\mathrm{E},k)}\rangle}{\sqrt{[\langle\left(\Delta t^{(\mathrm{E},0)}\right)^{2}\rangle-\langle\Delta t^{(\mathrm{E},0)}\rangle^{2}][\langle\left(\Delta t^{(\mathrm{E},k)}\right)^{2}\rangle-\langle\Delta t^{(\mathrm{E},k)}\rangle^{2}]}}, (19)

which is a dimensionless number between -1 and +1. In order to relate the index kk to a real time difference, we have introduced the variable Δt=kΔt\Delta t=k\langle\Delta t\rangle. Recall that 0Δt10s0\leq\Delta t\leq 10\,\mathrm{s}. Applied to the data files, the result of this whole operation is a set of 37 values of CE(Δt)C_{\mathrm{E}}(\Delta t) for each X=1,,33X=1,\ldots,33 and for the time-differences between the O-, H- and (O or H)-beam detection events. Note that if the Δti(E)\Delta t_{i}^{(\mathrm{E})}’s were independent random variables, we would have CE(Δt)=0C_{\mathrm{E}}(\Delta t)=0 for all Δt>0\Delta t>0.

In Fig. 6, we present the 33 plots as obtained from the time-differences between the O-beam detection events. These pictures show that

  1. 1.

    For several values of the phase shifter setting XX, the correlation CO(Δt)C_{\mathrm{O}}(\Delta t) exhibits oscillatory behavior. The period of the oscillations in the correlations is 𝒯2.8s{\cal T}\approx 2.8\;\mathrm{s}, independent of XX with amplitudes depending on XX.

  2. 2.

    As Δt10s\Delta t\rightarrow 10\;\mathrm{s}, the scattering of the points in the plots increases due to the fact that as kMk\rightarrow M, there are only a few data points per bin (0.01s0.01\;\mathrm{s} in this paper).

The plots of CH(Δt)C_{\mathrm{H}}(\Delta t) display less pronounced oscillations and those of COH(Δt)C_{\mathrm{OH}}(\Delta t) exhibit none at all, as illustrated in Fig. 7. Figure 8 shows the maximum amplitudes of the oscillations in CO(Δt)C_{\mathrm{O}}(\Delta t) and CH(Δt)C_{\mathrm{H}}(\Delta t) as a function of the phase shifter setting XX. As in the case of the standard deviations, there is a marked regularity in these data.

IV.2 Correlation in the time series of O- and H-counts

Additional evidence for the existence of long-time correlations in the detection events comes from the relative frequency with which say an O(H)-beam detection event (represented by xi=1(+1)x_{i}=-1(+1)) correlates with another O (H)-beam detection event (represented by xi+k=1(+1)x_{i+k}=-1(+1)) separated by k1k-1 other events (see also Table 1). This kind of information is contained in the correlation

Cx(Δt)\displaystyle C_{\mathrm{x}}(\Delta t) =\displaystyle= C(kΔt)x(0)x(k)x(0)x(k)[(x(0))2x(0)2][(x(k))2x(k)2],\displaystyle C(k\langle\Delta t\rangle)\equiv\frac{\langle x^{(0)}x^{(k)}\rangle-\langle x^{(0)}\rangle\langle x^{(k)}\rangle}{\sqrt{[\langle(x^{(0)})^{2}\rangle-\langle x^{(0)}\rangle^{2}][\langle(x^{(k)})^{2}\rangle-\langle x^{(k)}\rangle^{2}]}}, (20)
x(k)\displaystyle\langle x^{(k)}\rangle \displaystyle\equiv 1Mki=1Mkxi,(x(k))21Mki=1Mkxi2,x(0)x(k)1Mki=1Mkxixi+k.\displaystyle\frac{1}{M-k}\sum_{i=1}^{M-k}x_{i}\quad,\quad\langle(x^{(k)})^{2}\rangle\equiv\frac{1}{M-k}\sum_{i=1}^{M-k}x_{i}^{2}\quad,\quad\langle x^{(0)}x^{(k)}\rangle\equiv\frac{1}{M-k}\sum_{i=1}^{M-k}x_{i}x_{i+k}. (21)

As before, if the xix_{i}’s were independent random variables, we would have Cx(Δt)=0C_{\mathrm{x}}(\Delta t)=0 for all Δt>0\Delta t>0.

In Fig. 9, we present the 33 plots obtained by computing Eq. (20) using the same data files as those used to produce Fig. 6. The amplitudes of the oscillations in Cx(Δt)C_{\mathrm{x}}(\Delta t) are somewhat less pronounced than those in CO(Δt)C_{\mathrm{O}}(\Delta t) for the corresponding setting XX. Qualitatively, the xixi+kx_{i}-x_{i+k} correlations show the same features as the correlations of the time differences, suggesting that also the xix_{i}’s cannot be modeled by independent random variables.

Refer to caption
Figure 9: (color online) The correlation Cx(Δt)C_{\mathrm{x}}(\Delta t) of the variables xi=±1x_{i}=\pm 1 labeling O- or H-beam detection events (see Table 1) for different phase shifter settings XX as a function of the time difference Δt\Delta t, computed from the data. Fitting the data to the function f(Δt)=aexp(bΔt)cos(2πΔt/𝒯)f(\Delta t)=a\exp(-b\Delta t)\cos(2\pi\Delta t/{\cal T}) yields 𝒯2.8s{\cal T}\approx 2.8\;\mathrm{s} for the period of the oscillations in the correlation Cx(Δt)C_{\mathrm{x}}(\Delta t).

IV.3 Discussion

The correlations computed from the time-stamped data of repeated measurments of 10 s each exhibit oscillations, see Figs. 6 and 9. This observation is in conflict with a model based on independent random variables.

The same analysis was applied to the time series recorded on 19 June 2015 using polarized neutrons. These data have been obtained by using 45 s (instead of 10 s for the experiment with unpolarized neutrons) per setting XX, resulting in about 1.5 million time stamps collected over a time span of 3 hours and 22 minutes. The data for the correlations CO(Δt)C_{\mathrm{O}}(\Delta t) and Cx(Δt)C_{\mathrm{x}}(\Delta t) (see next section) suggest that the same oscillations are also present in this case. However, the statistics is too poor to allow for a reliable extraction of the period of the oscillations. The experiment with polarized neutrons was repeated on 25 and 26 June 2015, with 60 seconds instead of 45 s per setting XX, collecting about 2.1 million neutrons in about 9 hours and 13 minutes. The statistics of these data is not as good as for the data taken on 19 June 2015 and the evidence for oscillating correlations is very weak.

Computing the correlations using only the first five (twenty) seconds or the last five (twenty) seconds of data collected on 30 April 2015 (19 June 2015) per phase shifter setting has no significant effect on the visibility of the oscillations and therefore we do not show the corresponding figures.

The correlations obtained from the experiments with polarized neutrons show oscillations with much less visibility than the oscillations observed in the experiments with unpolarized neutrons. The former experiments were carried out with 45 and 60 s measurement time per setting. The latter experiments were carried out with 10 s measurement time per setting. Although the statistics of the former does not allow us to make a definite statement, the experimental data suggests that in all cases, the correlations CO(Δt)C_{\mathrm{O}}(\Delta t) and Cx(Δt)C_{\mathrm{x}}(\Delta t) show oscillations with a period of about 2.82.8\,s.

V Oscillating phase difference

The observed oscillations in the correlations Cx(Δt)C_{\mathrm{x}}(\Delta t) of the time series of the O- and H-counts as well as the ones observed in the correlations CE(Δt)C_{\mathrm{E}}(\Delta t) of the time-differences exhibit features that defy an explanation in terms of a quantum model of an ideal single-neutron interferometer. Indeed, in the latter model, these correlations are zero. In the case Cx(Δt)C_{\mathrm{x}}(\Delta t) for which we can associate projection operators to the observation of an O- or H-event we can, at least in principle, make use of the quantum formalism. However, in the case of CE(Δt)C_{\mathrm{E}}(\Delta t) there is no such association with operators of the quantum formalism Ballentine (2003). Indeed, quantum theory treats time as a parameter and not as an observable represented by an operator. The times at which the O- or H-detectors click refer to the readings of a clock, not to the measurement of some special “time variable”. In this sense, a calculation of CE(Δt)C_{\mathrm{E}}(\Delta t) is out of the scope of quantum theory.

We now show that the “unexplained” features can readily be reproduced by a single-neutron interferometer simulation model in which the phase difference oscillates in time. In other words, instead of having ΩOX+χO+ϵ\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}}+\epsilon as the expression of the phase difference in Eqs. (11) and  (12), we assume that we have

Ω~(t)=ΩOX+χO+ϵ+Ysin(ω(tt0)),\displaystyle\widetilde{\Omega}(t)=\Omega_{\mathrm{O}}X+\chi_{\mathrm{O}}+\epsilon+Y\sin(\omega(t-t_{0})), (22)

where YY is regarded as a new adjustable parameter and ω=2π/𝒯2π/2.8s1\omega=2\pi/{\cal T}\approx 2\pi/2.8\;\mathrm{s}^{-1} is the angular frequency of the oscillations in the correlation of time-differences. Note that we have taken as the period of these oscillations 𝒯2.8s{\cal T}\approx 2.8\;\mathrm{s}, the value observed in the experiment. The presence of the time offset t0t_{0} accounts for the lack of knowledge about the time at which the oscillation of the phase shift sets in, relative to the arrival time of the first neutron for the setting XX. As in our model for the standard deviation (see section III.2), ϵ\epsilon is chosen uniformly at random from the range [ϵ0,ϵ0][-\epsilon_{0},\epsilon_{0}] for each event. Simulations (data not shown) with ωt0\omega t_{0} chosen randomly do not reveal any significant dependence on ωt0\omega t_{0}. Therefore, for all practical purposes we may think of t0t_{0} being zero.

As the phase given by Eq. (22) explicitly depends on time, the time at which a neutron impinges on the first beam splitter BS0 of the interferometer affects its frequency to be detected in either the O-beam or H-beam detector. Therefore, in contrast to the standard treatment in terms of a stationary description, only a description that is intrinsically time-dependent can reproduce the oscillations in the correlation of the time-differences CO(Δt)C_{\mathrm{O}}(\Delta t). In essence, this enforces a description in terms of discrete events.

We consider two, conceptually very different, simulation models. Common to both models is that the times of the incident neutrons are generated according to a Poisson process, such that the average number of detected neutrons in the simulation is close to the one observed in experiment. The specifications of the models for the propagation of the individual neutrons through the interferometer and their detection process is given in the following two subsections.

V.1 Wave function collapse model

Refer to caption
Figure 10: (color online) The correlation CO(Δt)C_{\mathrm{O}}(\Delta t) of the time-differences between the O-beam detection events for different phase shifter settings XX as a function of the time difference Δt\Delta t, as obtained from the wave function collapse model with parameters AO=2745A_{\mathrm{O}}=2745, AH=4916A_{\mathrm{H}}=4916, BO=0.73B_{\mathrm{O}}=0.73, BH=0.42B_{\mathrm{H}}=0.42, ΩO=0.60\Omega_{\mathrm{O}}=0.60, χ0=2.7\chi_{0}=-2.7, ϵ0=0.13\epsilon_{0}=0.13, Y=0.2Y=0.2, t0=0t_{0}=0, and ω=2π/𝒯=2π/2.8s1\omega=2\pi/{\cal T}=2\pi/2.8\;\mathrm{s}^{-1}.

We scrutinize the “one particle is one wave packet” interpretation of quantum theory Rauch and Werner (2015); Ballentine (2003) by demonstrating that the standard way of invoking Born’s postulate and the wave function collapse may be reconciled with a description in terms of detection events and this without invoking the notion of instantaneous action on a distance, but only at the expense of attaching an extra attribute to the neutron. The arguments that are used to construct the model go as follows:

  1. (1)

    We assume that each neutron is accompanied by an “amplitude wave” that is propagating through space. At the beam splitters BS0, …, BS3 this amplitude wave is transmitted and reflected according to the rules of quantum theory.

  2. (2)

    We assume that it is possible to identify spatially localized “partial wave packets” that represent the probability for observing a single neutron in the different beams.

  3. (3)

    In line with (2), we assume that the partial wave that appears in the O(H)-beam determines the probability that the detector in the O(H)-beam fires.

  4. (4)

    The problem with the assumption in (3) is that there is a non-zero probability that both the detectors in the O- and H-beam fire simultaneously (meaning within the time resolution of the detection apparatus).

    For instance, for X=6X=6, the empirical frequencies for an O- or H-beam event are roughly equal to one half (see Fig. 4), implying that the frequency with which both detectors fire simultaneously is about 1/4.

    This is in blatant contradiction to the experimental data in which the frequency for observing a simultaneous O- and H-beam detection event is about 0.0000690.000069.

  5. (5)

    To get around the problem mentioned in (4), some interpretations of quantum theory invoke the elusive wave function collapse to avoid the clash with observed facts. We wrote “elusive” because after its introduction by Heisenberg in 1927, nobody has come up with a viable, realizable cause-and-effect model of how this wave function collapse is supposed to happen in the single-neutron experiments. In contrast, the statistical (= ensemble) interpretation does not make statements about single events and therefore it cannot be used to develop an event-based description Ballentine (2003).

  6. (6)

    Reasoning under the assumption that it is allowed to treat partial wave packets as independent entities, we attach a new attribute, called “A”, to the wave packet of each incident single neutron that enters the interferometer.

  7. (7)

    Whenever a wave packet splits in two or more parts (according to the rules of quantum theory), the attribute A is assigned to one of these parts according to the probability of that particular part. Other parts do not get the attribute A.

  8. (8)

    The key for making this artifice perform the “wave function collapse” is in the additional assumption that a neutron detector can only fire if it is hit by a wave packet that carries the attribute A.

  9. (9)

    As only one partial wave carries the attribute A, only one detector can fire at any time, i.e. this cause-and-effect mechanism implements the wave function collapse without invoking the notion of instantaneous action on a distance.

Simulating this wave function collapse model just outlined on a computer is very simple, namely generate either an O- or H-beam detection event with probability

P~O\displaystyle\widetilde{P}_{\mathrm{O}} =\displaystyle= AOAO+AH(1+BOcosΩ~(t)),\displaystyle\frac{A_{\mathrm{O}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\bigg{(}1+B_{\mathrm{O}}\cos\widetilde{\Omega}(t)\bigg{)}, (23)
P~H\displaystyle\widetilde{P}_{\mathrm{H}} =\displaystyle= AHAO+AH(1BOAOAHcosΩ~(t)),\displaystyle\frac{A_{\mathrm{H}}}{A_{\mathrm{O}}+A_{\mathrm{H}}}\bigg{(}1-\frac{B_{\mathrm{O}}A_{\mathrm{O}}}{A_{\mathrm{H}}}\cos\widetilde{\Omega}(t)\bigg{)}, (24)

respectively, where Ω~(t)\widetilde{\Omega}(t) is given by Eq. (22). The parameters AOA_{\mathrm{O}}, AHA_{\mathrm{H}}, BOB_{\mathrm{O}}, ΩO\Omega_{\mathrm{O}}, χ0\chi_{0}, and ϵ0\epsilon_{0} are fixed by fitting the counts and standard deviations (see section III).

The simulation results of the counts (not shown) and standard deviations (not shown) are very similar to those of the experiment. In Fig. 10 we present the simulation data of the correlation CO(Δt)C_{\mathrm{O}}(\Delta t) of the time-differences between the O-beam detection events. Comparing Fig. 10 with Fig. 6 suggests that the wave function collapse model based on Eqs. (23) and (24) reproduces the experimental findings quite well. When present, the oscillations in the correlation CO(Δt)C_{\mathrm{O}}(\Delta t) persist for longer times than in the case of the real experiment but that is to be expected because the wave function collapse model does not account for sources of disturbances other than the oscillating phase difference. Note that for fixed values of P~O\widetilde{P}_{\mathrm{O}} and P~H\widetilde{P}_{\mathrm{H}}, this model generates statistically independent detection events, the oscillations observed in the correlations being due to the variation of P~O\widetilde{P}_{\mathrm{O}} and P~H\widetilde{P}_{\mathrm{H}} with time only.

V.2 Discrete-event simulation

In the discrete-event simulation (DES) approach introduced in Ref. De Raedt et al., 2005, there is no wave accompanying the particle. Instead, interference results from the adaptive, cause-and-effect dynamics of the model of a beam splitter. In short, the application of DES to the single-neutron experiments is based on the following ideas:

Refer to caption
Figure 11: (color online) The correlation CO(Δt)C_{\mathrm{O}}(\Delta t) of the time-differences between the O-beam detection events for different phase shifter settings XX as a function of the time difference Δt\Delta t, as obtained from a discrete-event simulation of the idealized neutron interference experiment with an oscillating phase difference characterized by the parameters R=0.24R=0.24, γ=0.6\gamma=0.6 (parameters controlling the adaptive dynamics De Raedt et al. (2012); De Raedt and Michielsen (2012); Michielsen and De Raedt (2014) of each beam splitter), ΩO=0.60\Omega_{\mathrm{O}}=0.60, χ0=2.7\chi_{0}=-2.7, ϵ0=0.13\epsilon_{0}=0.13, Y=0.2Y=0.2, t0=0t_{0}=0, and ω=2π/𝒯=2π/2.8s1\omega=2\pi/{\cal T}=2\pi/2.8\;\mathrm{s}^{-1}.
  1. (1)

    We treat a neutron as a single “particle”, i.e. we do not need to introduce the concept of a wave function and its associated consequences for the measurement of the neutron, that is the wave function collapse.

  2. (2)

    Each neutron is processed one-by-one such that there is no direct interaction between the simulated neutrons.

  3. (3)

    As the neutrons are simulated as particles, a neutron can only take one path through the interferometer.

  4. (4)

    Each event registered by the O- or H-beam detector is caused by exactly one neutron entering the interferometer. By construction, it is impossible to have one neutron cause the O- and H-beam detectors to click simultaneously.

  5. (5)

    Single-neutron interference is the result of the adaptive dynamics of the beam splitter model. The adaptive dynamics itself is determined by the reflectivity RR and a parameter γ\gamma which controls the speed of adaptation. Input to the beam splitter model are the path on which the neutron enters and the time-of-flight of the neutron. The adaptive dynamics changes the internal state of the beam splitter model in a deterministic manner. The internal state determines the frequencies with which a neutron randomly leaves the beam splitter in either the O- or in the H-beam.

  6. (6)

    At no point in the formulation of the model, explicit use is made of expressions like Eqs. (23) and  (24). The input to the adaptive dynamic process results in updates of the internal state of the last beam splitter BS3. This state causes the neutrons to leave BS3 in the O- or H-beam with frequencies that agree with Eqs. (23) and  (24).

For a detailed account of the implementation of the DES and its applications to single-neutron experiments, see Refs. De Raedt et al., 2012; De Raedt and Michielsen, 2012; Michielsen and De Raedt, 2014.

The DES reproduces the data of the counts (data not shown) and of the standard deviation (data not shown) as a function of the setting XX. DES results of the correlation CO(Δt)C_{\mathrm{O}}(\Delta t) are shown in Fig. 11. Clearly, for all XX, the DES results for CO(Δt)C_{\mathrm{O}}(\Delta t) compare well with the corresponding entries in Fig. 6. When visible, the oscillations in the correlation CO(Δt)C_{\mathrm{O}}(\Delta t) persist for longer times than in the case of the real experiment but that is to be expected because the DES does not account for sources of disturbances other than the oscillating phase difference.

Figure 12 shows the maximum amplitudes of the oscillations in CO(Δt)C_{\mathrm{O}}(\Delta t) and CH(Δt)C_{\mathrm{H}}(\Delta t) as a function of the phase shifter setting XX, as obtained from the DES. Comparing Fig. 8 with Fig. 12, we conclude that DES reproduces the main features of the oscillations found in the experimental data.

Refer to caption
Figure 12: (color online) The maximum amplitudes of the oscillations in CO(Δt)C_{\mathrm{O}}(\Delta t) (\bigcirc) and CH(Δt)C_{\mathrm{H}}(\Delta t) (\Box), computed from the DES data, as a function of the phase shifter setting XX. Lines through the data points are guides to the eye.

Note that also in the DES model, the detection events are not statistically independent, the oscillations observed in the correlations being due to the variation of the path length with time. Obviously, the neutron data itself do not contain enough information to identify the source of these variations with certainty but plausible causes are small vibrations of the aluminum plate that is used for the phase shifter or small internal vibrations of the interferometer (i.e. the silicon single-crystal) itself, due to temperature or other environmental fluctuations.

VI Discussion

In this paper, we have presented a detailed analysis of the time series of time-stamped neutron counts obtained by single-neutron interferometry, the results of which can be summarized as follows:

  1. (1)

    The neutron counting statistics displays the Poissonian behavior as expected Rauch and Werner (2015).

  2. (2)

    The dependence of the variance of the neutron counts on the phase shifter setting can be explained by a probabilistic model that accounts for fluctuations of the phase shift.

  3. (3)

    The time series of the detection events exhibit long-time correlations, the amplitude of which depends on the phase shifter setting. These correlations appear as damped oscillations with a period of about 2.8 seconds, a fairly long time relative to the average time of 1.3 milliseconds between the detection of two successive neutrons. The cause of this oscillations is unknown. Viable candidate causes are fluctuations induced by temperature and/or vibrations.

  4. (4)

    We have shown by simulation that the correlations of the time differences observed in experiment can be reproduced by assuming that for a fixed setting of the phase shifter, the phase shift experienced by the neutrons varies periodically in time with a period of 𝒯2.8s{\cal T}\approx 2.8\;\mathrm{s}.

The results presented in this paper demonstrate that time-stamped data of single-particle interference experiments may exhibit features that go beyond the standard quantum model of independent random events and suggest instead a description in terms of non-stationary processes. With the available data, it is not possible to identify a cause for the observed correlations. It would be of interest to repeat the experiments with substantially longer measuring times and better statistics to see if the oscillations persist over a much longer time interval, before they disappear in the statistical noise. Another point to check might be the mechanical properties of the phase shifter, perhaps by using another one. Finally, although we have found the oscillations to persist over a long period, it might be worthwhile to repeat the same experiment, preferably at another neutron facility such as the one of NIST. If such an experiment confirms that the correlations exhibit oscillations with a frequency of about 2.8 seconds, the implication is that this phenomenon is beyond the prediction of a theory of independent random events.

Acknowledgements

We would like to thank Helmut Rauch, Koen De Raedt and Seiji Miyashita for helpful suggestions and discussions. This work is dedicated to the memory of Helmut Rauch.

References

  • Rauch and Werner (2015) H. Rauch and S. A. Werner, Neutron Interferometry: Lessons in Experimental Quantum Mechanics, Wave-Particle Duality, and Entanglement (Oxford, London, 2015).
  • Grimmet and Stirzaker (2001) G. R. Grimmet and D. R. Stirzaker, Probability and Random Processes (Clarendon Press, Oxford, 2001).
  • Rauch et al. (1974) H. Rauch, W. Treimer,  and U. Bonse, “Test of a single crystal neutron interferometer,” Phys. Lett. A 47, 369 – 371 (1974).
  • Kroupa et al. (2000) G. Kroupa, G. Bruckner, O. Bolik, M. Zawisky, M. Hainbuchner, G. Badurek, R. J. Buchelt, A. Schricker,  and H. Rauch, “Basic features of the upgraded S18 neutron interferometer set-up at ILL,” Nucl. Instrum. Methods Phys. Res. A. 440, 604 – 608 (2000).
  • Lemmel and Wagh (2010) H. Lemmel and A. G. Wagh, “Phase shifts and wave-packet displacements in neutron interferometry and a nondispersive, nondefocusing phase shifter,” Phys. Rev. A 82, 033626 (2010).
  • Zawisky et al. (1994) M. Zawisky, H. Rauch,  and Y. Hasegawa, “Contrast enhancement by time selection in neutron interferometry,” Phys. Rev. A 50, 5000–5006 (1994).
  • Rauch and Suda (1974) H. Rauch and M. Suda, “Intensitätsberechnung für ein Neutronen-Interferometer,” Phys. Stat. Sol. A 25, 495 – 505 (1974).
  • Horne (1986) M. A. Horne, “Neutron interferometry in a gravity field,” Physica B+C 137, 260 – 265 (1986).
  • Geppert et al. (2014) H. Geppert, T. Denkmayr, S. Sponar, H. Lemmel,  and Y. Hasegawa, “Improvement of the polarized neutron interferometer setup demonstrating violation of a Bell-like inequality,” Nucl. Instr. Methods A 763, 417 – 423 (2014).
  • Barlow (1989) R. Barlow, Statistics. A Guide to the Use of Statistical Methods in the Physical Sciences (Wiley, Chichester, UK, 1989).
  • Ballentine (2003) L. E. Ballentine, Quantum Mechanics: A Modern Development (World Scientific, Singapore, 2003).
  • De Raedt et al. (2005) K. De Raedt, H. De Raedt,  and K. Michielsen, “Deterministic event-based simulation of quantum phenomena,” Comp. Phys. Comm. 171, 19 – 39 (2005).
  • De Raedt et al. (2012) H. De Raedt, F. Jin,  and K. Michielsen, “Event-based simulation of neutron interferometry experiments,” Quantum Matter 1, 1 – 21 (2012).
  • De Raedt and Michielsen (2012) H. De Raedt and K. Michielsen, “Event-by-event simulation of quantum phenomena,” Ann. Phys. (Berlin) 524, 393 – 410 (2012).
  • Michielsen and De Raedt (2014) K. Michielsen and H. De Raedt, “Event-based simulation of quantum physics experiments,” Int. J. Mod. Phys. C 25, 01430003 (2014).