Improving resolution-sensitivity trade off in sub-shot noise imaging
Abstract
One of the challenges of quantum technologies is realising the quantum advantage, predicted for ideal systems, in real applications, which have to cope with decoherence and inefficiencies. In quantum metrology, sub-shot-noise imaging (SSNI) and sensing methods can provide genuine quantum enhancement in realistic situations. However, wide field SSNI schemes realized so far suffer a trade-off between the resolution and the sensitivity gain over classical counterpart: small pixels or integrating area, are necessary to achieve high imaging resolution, but larger pixels allow a better detection efficiency of quantum correlations, which means a larger quantum advantage. Here we show how the SSNI protocol can be optimized to significantly improve the resolution without giving up the quantum advantage in the sensitivity. We show a linear resolution improvement (up to a factor 3) with respect to the simple protocol used in previous demonstrations.
I Introduction
Imaging delicate systems using small number of incident photons with true and significant quantum enhanced sensitivity is extraordinarily important for applications, from biology and medicine to fundamental physics research. The first proof of principle of SSNI of a 2D absorption/transmission mask was given in 2010 Brida2010 and in 2017 we reported the realization of the first wide field sub shot noise microscope Samantaray2017 . It is based on spatially multi-mode non-classical photon number correlations of two-mode squeezed vacuum (TMSV) states, produced by Spontaneous parametric down conversion (SPDC) and detected by a high quantum efficiency CCD camera jedrkiewicz2004 ; brida2009 ; blanchet2008 ; gatti2008 ; Genovese16 . The sample (2D mask) is probed by one beam with certain level of quantum fluctuations, so that the detected image is affected by a noise pattern. However, a second reference beam, locally correlated in the photon number with the first one, generates at the detector an identical noise pattern. In this way, one can simply remove the noise by subtraction. The microscope of Ref. Samantaray2017 produces real-time images of several thousands pixels and m of resolution even though the actual quantum enhancement in sensitivity compared with the best classical protocol is effective at larger spatial scales. In fact, in this technique there is a clear trade-off between the resolution and the quantum enhancement, due to the fact that pixels or integrating areas smaller than the characteristic size of the spatial modes do not intercept all the correlated photons between pairs of conjugated modes. With the aim of improving the performance of this technique, in Ref. Losero18 we studied in deep detail the problem of absorption estimation by photon counting towards the ultimate quantum limit, taking into account experimental inefficiencies. In particular, we analytically showed the advantage of the optimized estimator proposed in Moreau2017 , especially in case of limited detection efficiency. This estimator does not involve modification of the set-up, but only a slightly different use of the data and a pre-calibration of the system.
Here we use this estimation protocol to shift the resolution-sensitivity trade-off of the SSNI, improving the resolution of a factor 3 in the best case. It turns out that in this way it is in principle possible to obtain SSNI at the Rayleigh resolution limit.
II Estimation of a loss with TMSV state
The lower bound to the uncertainty in a loss estimation for classical probes, i.e. mixture of coherent states, is pirandola2017
(1) |
where is the mean number of photons of the probe and is the loss induced by the the sample. Only for high losses the uncertainty can be arbitrary small, while in case of a faint loss, one retrieves the expression , usually referred as to "shot-noise-limit" (SNL).
In general, excluding adaptive strategies where the limit is still unknown pirandola2017 , the ultimate quantum limit (UQL) of sensitivity for a single mode probe is paris2007 ; adesso2009 , which scales much more favorably than the classical bound for small losses. Several quantum states have been demonstrated to reach in principle this ultimate limit: single mode squeezed vacuum, with detection strategy based on photon counting and Gaussian operations, for small losses and small number of photons paris2007 ; Fock states , with photon counting, unconditionally for any but if adesso2009 ; TMSV state with photon counting Nair18 , unconditionally for any loss and all energy regimes illuminati . TMSV being the photon number entangles state:
(2) |
where the subscripts "1" and "2" represent two correlated modes, and the probability amplitude is , being the mean number of photons per mode.
On the experimental side, a seminal proposal on absorption measurement with photon pairs produced by SPDC, i.e. using a faint TMSV state, was given already in 1986 Jakeman86 and a sub-shot-noise measurement of modulated absorption using SPDC has been realized few years laterTapster1991 . More recently, quantum enhanced absorption measurements have been performed by post-selected heralded single photon Fock states Whittaker2017 and also trough an active feed-forward driven by an optical shutter sabines2017 . In those cases, on/off single photon detectors have been used. However, the higher genuine quantum enhancement has been achieved in experiments exploiting low noise intensity measurement (photon counting), taking advantage of the high quantum efficiency and small electronic noise of the modern CCD cameras Moreau2017 ; Losero18 . An enhancement of the order of 50% respect to the classical bound has been achieved for the same number of detected photons and 32% if perfect detection efficiency is considered only for the classical scheme Losero18 . With these detectors, that provide also flexible spatial resolution, and exploiting the spatially multimode emission of traveling wave SPDC it has been possible to devise gatti2008 , and realize Brida2010 ; Brida11 ; Samantaray2017 wide field SSNI schemes where a 2D amplitude mask is recovered by parallel multi-parameter absorption/transmission estimation.
Ref. Losero18 , reports a systematic study of the performance achieved by several possible estimation strategies based on the detected number of photons jointly measured in the probe, , and reference . Summarizing, three estimators have been considered there:
-
•
Ratio, as used for example in Jakeman86
(3) -
•
Subtraction, considered for SSNI gatti2008 ; Brida2010 ; Brida2010 ; Samantaray2017
(4) -
•
Optimized subtraction, considered in Tapster1991 and Moreau2017
(5)
The factor is introduced to account for unbalancing between the mean energy detected in the probe and reference arm without the sample. It can be evaluated in a pre-calibration of the apparatus, that should last long enough to provide an accurate determination of . In the third estimator, the factor must be optimized in function of the physical parameters of the system. In particular it turns out that is a function of the detection efficiencies of the channels and the local excess noise. Clearly, each of the three estimation strategies is based on the idea that the common photon number fluctuations of the probe and reference beam can be suppressed or at least mitigated by a direct comparison. However, in terms of the uncertainty they behave differently. For the general expressions the reader should refer to Ref. Losero18 . For simplicity, here we consider the same detection efficiency in the two arms, i.e. . Moreover, we consider a large number of spatio-temporal realization of TMSV states (here collectively named twin-beam state), detected by each pixel in the measurement time, and mean number of photons per mode . The last constraints allow considering each pixel with Poissonian photon number distribution and to be independent from the others in the same arm. In this case one has:
-
•
Uncertainty of the Ratio
(6) -
•
Uncertainty of the Subtraction
(7) -
•
Uncertainty of the Optimized subtraction
(8)
In the equations above, the parameter () is related to the noise reduction factor agafonov2011 ; bondani2007 ; iskhakov2016 by the relation . The NRF represents the level of correlation of the joint detected photon number distributions, and can be estimated experimentally. For , the correlations are non-classical. Therefore, can be interpreted as the efficiency in detecting correlated photons, i.e. the probability that for a photon detected in a certain pixel in the probe arm, its twin photon is detected in the correlated pixel in the reference arm. Thus, it can be written as the product of the channel detection efficiency and a collection efficiency term, . The collection efficiency takes into account for the fact that in real systems correlated modes cannot be always perfectly detected.
In the ideal situation, assuming , both the Ratio in Eq. 3 and the Optimized estimator in Eq. 5 reach the UQL, while the Subtraction estimator in Eq. 4 approaches the UQL only asymptotically for small value of the loss .
However, another significant difference appears in the non ideal detection case, because of the different dependence of Eq.s 6-8 from . In particular, for the Ratio and the Subtraction estimators, the positive additive term exceeding the UQL is , which is larger than the one for the Optimized case , for any value of . This means that the Optimized estimator works always better than the others, and that this advantage is larger for low efficiency . For example, rewriting the Eq.s 6-8 in terms of the classical bound of Eq. 1, it is easy to see that the quantum advantage for the Ratio or the Subtraction estimators starts from . In contrast, the twin beam state together with the Optimized subtraction protocol performs always better than the classical bound.
In the next section we will show how this feature of the Optimized estimator is particularly suited for the SSNI improvement also in terms of resolution.

III SSNI: Experimental Results
In wide field imaging realizations with SPDC Brida2010 ; Samantaray2017 , the spatial pattern in the far field of the emission, where the transmitting mask is placed, is a continuous distribution of independent spatial modes with a certain coherence area given by the Fourier transform of the pump beam profile. This plane is then projected at the pixel’s matrix of the detector chip, where probe and reference beams are detected in two different regions. Fig. 1 describes the details of our experimental set-up.
The pixel size, or more in general the elementary integration area in one arm, should be large enough to collect a certain number of modes. It is straightforward that if a photon is detected in a certain pixel in the probe arm, the corresponding pixel in the reference arm should be at least as large as the correlation area, otherwise correlated photons would fall outside the pixel, representing an effective loss when pixel to pixel correlations are considered. Moreover, a photon detected close to the edge between a pixel and its neighbors, has its twin photon detected with only <50% probability in the symmetric pixel in the reference arm. Both these contributions to losses are taken into account by , enclosed in in Eq.s 6-8. In the conditions of our experiment, and assuming a perfect alignment, is solely related to the ratio , being the pixel size and the transverse correlation radius. Details of this model can be found in previous literature Samantaray2017 ; Meda14 ; Meda17 .
In Fig. 2 we report the experimental in function of the resolution, i.e. the size of the integration area . It decreases with , as long as the collection efficiency increases, saturating the value for (where ). In the same figure also the quantum enhancement in the sensitivity is reported, in function of the resolution. Of course, in general, a suitable trade-off between the resolution , and the sensitivity should be found. The dashed red curve represents the quantum advantage of the twin beam using the Subtraction estimator. It is evaluated as , replacing in the Eq.s 1 and 7 the values of and with their experimentally estimated values. Solid red line represents the corresponding quantum enhancement for the Optimized estimation. The data-points represent, for each case, the quantum advantage estimated by the experimental frame-to-frame fluctuation in the absorption determination, according to Eq.s 4-5 respectively. 300 shots and region where are used. The experimental classical uncertainty to compare with, is obtained by the fluctuation of the estimate in Eq. 3, where the reference is substituted by the mean value of the probe in absence of the sample . This estimator, using only the probe beam, reaches the lower classical bound , so it represents the best classical strategy Losero18 .
As we have anticipated at the end of Sec. II, the quantum advantage when using the Subtraction, as done in previous demonstration Samantaray2017 , is present for (red dashed line in Fig. 2). It corresponds to a resolution of 3 times the correlation length, namely 15 m. We can conclude that, with this estimator it is not possible, even in principle, to have quantum enhancement and a resolution close to a single coherence length, at the same time.
In this context, the Optimized estimator is a big opportunity because its quantum advantage can be found also for smaller value of the efficiency or equivalently for . In fact, the solid line in Fig. 2 shows that the quantum advantage is present also for m which is exactly the coherence length. Moreover this estimator performs better than the other one for any resolution, always representing the best choice for SSNI in wide field modality.
As mentioned, the only point that deserves attention when using the optimized estimator, is that it requires a careful characterization of the experimental setup, in order to provide a reliable value of the parameter to insert in Eq. 5. This is a simple function of the excess noise end the detection efficiencies in both channels. We estimated the absolute quantum efficiency with a method that can be applied with an identical setup configurationMeda14 . We found that the performance of the Optimized estimator is not dramatically affected by the accuracy in the parameter’s determination: few percent of uncertainty is enough to recover the advantage predicted by the theory.

Finally, in Fig.3 we present a single frame experimental image of a specific absorbing mask for different spatial resolutions. The mask is realized by a thin "-shaped" metallic deposition on a coated glass-slide with . The resolution is set by the application of a median filter, which substitutes in each pixel (corresponding to m in the object plane) the mean photon counts over a square of side , centered in the pixel. As expected, the images obtained with the quantum protocol, i.e. using the twin-beam state, are visually better than the ones obtained by single beam classical approach. Moreover, one can appreciate an improvement of the Optimized estimation protocol with respect to the Subtraction protocol in the residual noise level.

IV Conclusion
In this letter, we have shown a substantial improvement of the performance of the SSNI technique with respect to previous realizations Brida2010 ; Samantaray2017 ; sabines19 . By studying different pure loss estimations strategies with quantum states of light in presence of imperfections we demonstrate that the robustness of an Optimized estimator with respect to detection losses, and the link between spatial resolution and inefficiencies in detecting correlated photons, implies that such estimator produces a significant advantage also in terms of resolution. We have demonstrated that, differently from the previous Subtraction protocol, the limit to the resolution is given by the coherence area of the correlation in the far field of the SPDC process, that can be in principle reduced down to the Rayleigh limit determined by the numerical aperture of the optical system. This result represents a further step toward practical applications of quantum correlations in imaging.
Acknowledgements.
This work has been supported by EMPIR 17FUN01 ‘BeCOME’, the EMPIR initiative is co-funded by the EU H2020 and the EMPIR Participating States, and by the Horizon 2020 research and innovation program under grant agreement number 862644 (FETopen- QUARTET).References
- (1) Brida, G., Genovese, M., & Berchera, I. R. Experimental realization of sub-shot-noise quantum imaging. Nature Photonics 4(4), 227-230 (2010).
- (2) Samantaray, N., Ruo-Berchera, I., Meda, A., & Genovese, M. Realisation of the first sub shot noise wide field microscope. Light: Science & Applications 6, e17005 (2017).
- (3) Jedrkiewicz, O., Jiang, Y. K., Brambilla, E., Gatti, A., Bache, M., Lugiato, L. A. & Di Trapani, P. Detection of Sub-Shot-Noise Spatial Correlation in High-Gain Parametric Down Conversion. Physical Review Letter 93, 243601 (2004).
- (4) Brida, G., Caspani, L., Gatti, A., Genovese, M., Meda, A. & Ruo-Berchera, I. Measurement of sub shot-noise spatial correlations without background subtraction. Physical Review Letter 102, 213602 (2009).
- (5) Blanchet, J. L., Devaux, F., Furfaro, L. & Lantz, E. Measurement of sub-shot-noise correlations of spatial fluctuations in the photon-counting regime. Physical Review Letter 101, 233604 (2008).
- (6) Brambilla, E., Caspani, L., Jedrkiewicz, O., Lugiato, L. A., & Gatti, A. High-sensitivity imaging with multi-mode twin beams. Physical Review A 77(5), 053807 (2008).
- (7) Genovese, M., Real applications of quantum imaging, Journal of Optics, 18 073002 (2016).
- (8) Losero E, Ruo-Berchera I, Meda A, Avella A and Genovese M, Unbiased estimation of an optical loss at the ultimate quantum limit with twin-beams, Sci. Rep. 8, 7431 (2018)
- (9) Moreau, P. A., Sabines-Chesterking, J., Whittaker, R., Joshi, S. K., Birchall, P. M., McMillan, A., Rarity, J. G. & Matthews J. C. F. Demonstrating an absolute quantum advantage in direct absorption measurement, Scientific Reports 7, 6256 (2017).
- (10) Braun, D., Adesso, G., Benatti, F., Floreanini, R., Marzolino, U., Mitchell, M. W., & Pirandola, S. Quantum enhanced measurements without entanglement. arXiv preprint arXiv:1701.05152 (2017).
- (11) Monras, A., & Paris, M. G. Optimal quantum estimation of loss in bosonic channels. Physical review letters 98(16), 160401 (2007).
- (12) Adesso, G., Dell’Anno, F., De Siena, S., Illuminati, F., & Souza, L. A. M. Optimal estimation of losses at the ultimate quantum limit with non-Gaussian states. Physical Review A 79(4), 040305 (2009).
- (13) R. Nair, Quantum-Limited Loss Sensing: Multiparameter Estimation and Bures Distance between Loss Channels, Phys. Rev. Lett. 121, 230801 (2018).
- (14) Monras, A. & Illuminati, F. Measurement of damping and temperature: Precision bounds in Gaussian dissipative channels. Physical Review A 83(1), 012315 (2011).
- (15) Jakeman, E. & Rarity, J.G. The use of pair production processes to reduce quantum noise in transmission measurements. Optics Communications 59(3), 219-223 (1986)
- (16) Tapster, P., Seward, S. & Rarity, J. Sub-shot-noise measurement of modulated absorption using parametric down-conversion. Physical Review A 44, 3266 (1991).
- (17) Whittaker, R., Erven, C., Neville, A., Berry, M., O’Brien, J. L., Cable, H., & Matthews, J. C. F. Absorption spectroscopy at the ultimate quantum limit from single-photon states. New Journal of Physics 19(2), 023013 (2017).
- (18) Sabines-Chesterking, J., Sub-Shot-Noise Transmission Measurement Enabled by Active Feed-Forward of Heralded Single Photons. Physical Review Applied 8, 014016 (2017).
- (19) Brida, G., Genovese, M., Meda, A. & Ruo-Berchera, I. Experimental quantum imaging exploiting multimode spatial correlation of twin beams. Physical Review A 83, 033811 (2011).
- (20) Agafonov, I. N., Chekhova, M. V., Sh Iskhakov, T., Penin, A. N., Rytikov, G. O. & Shcherbina, O. A. Absolute calibration of photodetectors: photocurrent multiplication versus photocurrent subtraction. Optics Letters 36(8), 1329-1331 (2011).
- (21) Bondani, M., Allevi, A., Zambra, G., Paris, M. & Andreoni, A. Sub-shot-noise photon-number correlation in a mesoscopic twin beam of light. Physical Review A 76, 013833 (2007).
- (22) Iskhakov, T. S., Usenko, V. C., Andersen, U. L., Filip, R., Chekhova, M. V. & Leuchs, G. Heralded source of bright multi-mode mesoscopic sub-Poissonian light. Optics Letters 41, 2149-2152 (2016).
- (23) A Meda, E Losero, N Samantaray, F Scafirimuto, S Pradyumna, A Avella, I Ruo-Berchera and M Genovese, Photon-number correlation for quantum enhanced imaging and sensing, Journal of Optics 19, 094002 (2017).
- (24) Meda, A., Ruo-Berchera, I., Degiovanni, I. P., Brida, G., Rastello, M. L. & Genovese, M. Absolute calibration of a charge-coupled device camera with twin beams. Applied Physics Letter 105, 101113 (2014).
- (25) Sabines, J., McMillan, A., Moreau P., Joshi S., Knauer, S., Johnston, E., Rarity, J., Matthews J., Twin-beam sub-shot-noise raster-scanning microscope with a hybrid detection scheme, arXiv:1906.05331.