This paper was converted on www.awesomepapers.org from LaTeX by an anonymous user.
Want to know more? Visit the Converter page.

Estimation of losses in a 300 m filter cavity and quantum noise reduction in the KAGRA gravitational-wave detector

Eleonora Capocasa1,2 [email protected]    Matteo Barsuglia1    Jérôme Degallaix3    Laurent Pinard3    Nicolas Straniero3    Roman Schnabel 4    Kentaro Somiya5    Yoichi Aso2    Daisuke Tatsumi2    Raffaele Flaminio2 1APC, AstroParticule et Cosmologie, Université Paris Diderot, CNRS/IN2P3, CEA/Irfu, Observatoire de Paris, Sorbonne Paris Cité, 10, rue Alice Domon et Léonie Duquet, 75205 Paris Cedex 13, France 2National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo, 181-8588, Japan 3Laboratoire des Matériaux Avancés, CNRS-IN2P3, Université de Lyon, Villeurbanne, France 4Institut für Laserphysik und Zentrum fur Optische Quantentechnologien der Universitat Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany 5Graduate School of Science and Technology, Tokyo Institute of Technology, 2-12-1 Oh-okayama, Meguro, Tokyo, 152-8551, Japan
Abstract

The sensitivity of the gravitational-wave detector KAGRA, presently under construction, will be limited by quantum noise in a large fraction of its spectrum. The most promising technique to increase the detector sensitivity is the injection of squeezed states of light, where the squeezing angle is dynamically rotated by a Fabry-Pérot filter cavity. One of the main issues in the filter cavity design and realization are the optical losses due to the mirror surface imperfections. In this work we present a study of the specifications for the mirrors to be used in a 300 m filter cavity for the KAGRA detector. A prototype of the cavity will be constructed at the National Astronomical Observatory of Japan (NAOJ), inside the infrastructure of the former TAMA interferometer. We also discuss the potential improvement of the KAGRA sensitivity, based on a model of various realistic sources of losses and their influence on the squeezing amplitude.

I Introduction

Quantum noise is one of the main limiting factors for second generation gravitational-wave interferometric detectors, such as KAGRA KAGRA , Advanced LIGO aLIGO_CQG and Advanced Virgo AdV_CQG . As pointed out by Caves in 1981 Caves , the two manifestations of quantum noise, shot noise and radiation pressure noise, are created by vacuum fluctuations entering the interferometer by the antisymmetric (or dark) port. Caves also proposed the injection of a squeezed vacuum from the dark port as a strategy to decrease quantum noise without modifying the interferometer configuration.

In a squeezed vacuum state, the amplitude and phase uncertainty, equally distributed in an ordinary vacuum, are modified in order to reduce one at the expense of the other. If this is a pure state, it can be represented as an ellipse in the quadrature plane and it is characterized by the ratio of its axes (squeezing magnitude) and by its orientation (squeezing angle). Both of these parameters are functions of the Fourier frequency. If the quadrature with the reduced uncertainty is aligned in the gravitational wave signal, the signal to noise ratio is improved with respect to that achievable with an ordinary vacuum. Since the optomechanical coupling of the laser light with the interferometer test masses induces a rotation of the squeezing ellipse, the injection of a frequency-independent squeezed vacuum (i.e with constant squeezing angle) will mitigate quantum noise only in the part of the spectrum where the gravitational-wave signal is aligned with quadrature with reduced uncertainty. In the case of a phase quadrature squeezing, the improvement is the same as that achievable by increasing the laser power.

A broadband quantum noise reduction can be obtained by injecting a squeezed vacuum with an angle that varies with frequency, in such a way that the signal and reduced noise quadrature are always aligned kimble . This frequency dependent squeezing can be obtained by reflecting off a frequency-independent squeezed state by a detuned Fabry-Pérot filter cavity. The rotation of the squeezing angle has been experimentally demonstrated in the MHz regionChe and, more recently, in the kHz regionOel .

The injection of frequency dependent squeezing is particularly suitable for a future upgrade of KAGRA, since increasing laser power to reduce shot noise can be difficult due to the cryogenic temperature of the detector. Moreover, since thermal noise is low enough to make quantum noise the dominant contribution in a large part of the spectrum, the reduction of quantum noise would have a direct and significant effect on the detector sensitivity.

The achievement of a high level of frequency dependent squeezing faces two kinds of difficulties. First, the squeezing angle should undergo a rotation in the frequency region where quantum noise switches from radiation pressure noise to shot noise (70\sim 70 Hz for KAGRA). This corresponds to a filter cavity with a very long storage time of 2\sim 2 ms. Moreover, the presence of optical losses in the filter cavity system will decrease the squeezing factor, since losses are associated with ordinary vacuum fluctuations which couple with the squeezed states reducing their squeezing level. For both these reasons, optical losses in the filter cavity system should be estimated and reduced as much as possible.

A 300 m prototype of the cavity will be developed at NAOJ, using the former TAMA infrastructure TAMA . This is, to our knowledge, the longest filter cavity prototype under construction. Previous experiments were made using a 2 m long cavity Oel . The first goal of this paper is to present the filter cavity optical design. One of the main issues in the filter cavity realization are the losses due to the mirror surface imperfections. In this work we present a study of the specifications for the mirrors, based on real mirror maps, used in the Virgo experiment. Moreover, a crucial point is to compare the squeezing degradation from the filter cavity optical losses with those originated by other mechanisms. Thus, we present a complete squeezing degradation budget for the 300 m cavity, based on the work by Kwee et al.sq2 . We finally discuss the potential improvement of KAGRA sensitivity using the 300 m filter cavity, compatible with the KAGRA infrastructure.

The interest of this work goes beyond KAGRA, since a 100-m class filter cavity is also a possible solution for a medium-term upgrade of Advanced Virgovirgo_sqz , and 300 m filter cavities are planned for the 3rd generation detector Einstein TelescopeET . The structure of the article is as follows: in section II we demonstrate the computation of the filter cavity parameters needed to obtain an optimal rotation of the squeezing angle for KAGRA. In section III the filter cavity numerical simulation, with realistic mirror maps, is presented. In section IV an estimation of the squeezing degradation, due to cavity losses and other degradation mechanisms, is obtained. Finally, the expected improvement in KAGRA sensitivity, achievable using frequency-dependent squeezing, is presented.

II Filter cavity optical design

In the first part of this section we discuss the choice of finesse and detuning of the filter cavity. In the second part, we address the problem of the choice of cavity length, mirror dimension and radius of curvature.

II.0.1 Length, finesse and detuning

Filter cavity bandwidth and detuning should be chosen in order to allow an optimal rotation angle of the squeezed state to be injected in the interferometer dark port. This rotation should counteract that which is produced by the interferometer, keeping the squeezing state aligned with the signal quadrature at all frequencies. The optimal rotation angle of the cavity is therefore a function of the interferometer parameters Harms :

θfc(Ω)=arctan(K(Ω))\theta_{\mathrm{fc}}(\Omega)=\arctan(K(\Omega)) (1)

with KK being the frequency dependent optomechanical coupling, whose dependance from the signal sideband frequency Ω\Omega given by:

K(Ω)=(ΩSQLΩ)2γifo2Ω2+γifo2K(\Omega)=\left(\frac{\Omega_{\mathrm{{SQL}}}}{\Omega}\right)^{2}\frac{\gamma^{2}_{\mathrm{{ifo}}}}{\Omega^{2}+\gamma^{2}_{\mathrm{{ifo}}}} (2)

where γifo2\gamma^{2}_{\mathrm{ifo}} is the interferometer bandwidth and ΩSQL\Omega_{\mathrm{SQL}} is the frequency at which quantum noise reaches the standard quantum limitBrag , marking the transition between radiation pressure noise and shot noise. In a dual recycled interferometer, with a tuned signal-recycling cavity, we have:

ΩSQL=[tsr1+rsr]8cParmω0mTarm\Omega_{\mathrm{SQL}}=\left[\frac{t_{\mathrm{sr}}}{1+r_{\mathrm{sr}}}\right]\frac{8}{c}\sqrt{\frac{P_{\mathrm{arm}}\omega_{0}}{mT_{\mathrm{arm}}}} (3)

and

γifo=[1+rsr1rsr]Tarmc4Larm\gamma_{\mathrm{ifo}}=\left[\frac{1+r_{\mathrm{sr}}}{1-r_{\mathrm{sr}}}\right]\frac{T_{\mathrm{arm}}c}{4L_{\mathrm{arm}}} (4)

where tsrt_{\mathrm{sr}} and rsrr_{\mathrm{sr}} are the signal recycling mirror amplitude transmissivity and reflectivity, ParmP_{\mathrm{arm}} is the intracavity power, TarmT_{\mathrm{arm}} is the arm cavity input mirror power transmissivity, ω0\omega_{0} is the angular frequency of the carrier field, mm is the mirror mass.

For KAGRA, using the parameters shown in Tab. 1, we have:

ΩSQL=2π×76.4Hz\Omega_{\mathrm{SQL}}=2\pi\times 76.4\,\mathrm{Hz} (5)

and

γifo=2π×382Hz\gamma_{\mathrm{ifo}}=2\pi\times 382\,\mathrm{Hz} (6)

For Ω<<γifo\Omega<<\gamma_{\mathrm{ifo}} Eq.2 can be simplified and we are in the region of interest. The required rotation angle then becomes:

θfc(Ω)=arctan(ΩSQLΩ)2\theta_{\mathrm{fc}}(\Omega)=\arctan\left(\frac{\Omega_{\mathrm{{SQL}}}}{\Omega}\right)^{2} (7)
Parameter Symbol Value
Carrier field frequency ω0\omega_{0} 2π×282THz2\pi\times 282\,\mathrm{THz}
Standard quantum limit frequency ΩSQL\Omega_{\mathrm{SQL}} 2π×76.4Hz2\pi\times 76.4\,\mathrm{Hz}
Arm input mirror transmissivity TarmT_{\mathrm{arm}} 0.004
Signal recycling input transmissivity tsr2t^{2}_{\mathrm{sr}} 0.1536
Intracavity power ParmP_{\mathrm{arm}} 400kW400\,\mathrm{kW}
Mirror mass mm 22.8kg22.8\,\mathrm{kg}
Table 1: Values and symbols for KAGRA interferometer parameters.

In order to obtain the above frequency dependent rotation, the bandwidth γfc\gamma_{\mathrm{fc}} and the detuning Δωfc\Delta\omega_{\mathrm{fc}} of a lossless filter cavity should be:

γfc=ΩSQL2\gamma_{\mathrm{fc}}=\frac{\Omega_{\mathrm{{SQL}}}}{\sqrt{2}} (8)
Δωfc=γfc\Delta\omega_{\mathrm{fc}}=\gamma_{\mathrm{fc}} (9)

As discussed in sq2 , in presence of losses, the bandwidth and the detuning of the filter cavity become:

γfc=2(2ϵ)1ϵΩSQL2\gamma_{\mathrm{fc}}=\sqrt{\frac{2}{(2-\epsilon)\sqrt{1-\epsilon}}}\frac{\Omega_{\mathrm{SQL}}}{\sqrt{2}} (10)
Δωfc=γfc1ϵ\Delta\omega_{\mathrm{fc}}=\gamma_{\mathrm{fc}}\sqrt{1-\epsilon} (11)

where ϵ\epsilon is a function of the filter cavity round trip losses Λrt2\Lambda^{2}_{rt}, the free spectral range fFSR=c/2Lfcf_{\mathrm{FSR}}=c/2L_{\mathrm{fc}}, and ΩSQL\Omega_{\mathrm{SQL}}:

ϵ=42+2+21+(2ΩSQLfFSRΛrt2)4\epsilon=\frac{4}{2+\sqrt{2+2\sqrt{1+\left(\frac{2\Omega_{\mathrm{SQL}}}{f_{\mathrm{FSR}}\Lambda^{2}_{rt}}\right)^{4}}}} (12)

Given a filter cavity with fixed length and losses, we can compute the parameter ϵ\epsilon using Eq. 12. Then, using Eq. 10 and 11, we obtain the optimal bandwidth and detuning. Finally, in order to compute the cavity finesse, we can write the bandwidth γfc\gamma_{\mathrm{fc}} of a Fabry-Pérot cavity in terms of the losses, length and input mirror transmissivity tin2t^{2}_{\mathrm{in}}:

γfc=tin2+Λrt22fFSR\gamma_{\mathrm{fc}}=\frac{t^{2}_{\mathrm{in}}+\Lambda^{2}_{rt}}{2}f_{\mathrm{FSR}} (13)

Inverting the previous equation, we can finally compute tin2t^{2}_{\mathrm{in}} which determines the cavity finesse.

The length of the filter cavity is set to 300 m, corresponding to the length of the arms of the former TAMA interferometer. The losses Λrt2\Lambda^{2}_{rt} are set to 80 ppm, a value which will be justified in the following section. For these values, we found ϵ=0.111\epsilon=0.111 and γfc=2π×57.3\gamma_{\mathrm{fc}}=2\pi\times 57.3. The optimal detuning will be Δωfc=2π×54Hz\Delta\omega_{\mathrm{fc}}=2\pi\times 54\,\mathrm{Hz} and tin2=0.0014t^{2}_{\mathrm{in}}=0.0014, corresponding to a finesse of 44804480. We highlight the fact that for Λrt2\Lambda^{2}_{rt} up to 700\sim 700 ppm, the value of the finesse is almost independent of the cavity losses.

II.0.2 Mirrors dimension and radius of curvature (RoC)

In order to reduce the losses due to the finite size of the mirrors (clipping losses), we require the size of the beam to be as small as possible. As shown in fab , this is also the best way to reduce the effects of large-scale mirror defects. The confocal configuration (radii of curvature equal to the cavity length) gives the smallest beam radius on the mirrors, but this configuration is marginally stable. We choose radii 400\sim 400 m, reasonably larger than 300 m, to avoid cavity instability. The exact value of the RoC will be determined using numerical simulations, described in the next paragraph, in order to minimize the losses.

For a 300 m cavity with two mirrors with a RoC of 400 m, the beam diameter at the waist and on the mirrors is respectively 0.0162 m and 0.0205 m. Choosing, as it was done for TAMA, mirrors with a diameter of 0.1 m, (roughly five time bigger that the beam radius) results in completely negligible clipping losses.

The filter cavity parameters are reported in Tab. 2

Parameter Symbol Value
Length LL 300300 m
Radius of curvature RoC variable
Mirror diameter dd 0.10.1 m
Input mirror transmissivity tin2t^{2}_{\mathrm{in}} 0.0014
Finesse FF 44804480
Beam diameter at waist(RoC 400 m) 0.01620.0162 m
Beam diameter at the mirror(RoC 400 m) 0.02050.0205 m
Table 2: Filter cavity parameters.

III Mirror surface quality specifications

The presence of losses in the filter cavity, caused by mirror defect and mirror finite size, induces squeezing degradation. In this section we will detail the procedure needed to find the specifications on mirror dimensions and surface flatness.

Mirror defects, namely deviations of the mirror surface from a perfect spherical one, are described by the mirror map, which is a square matrix of nn elements with n=lmir/resn=l_{mir}/res, where lmirl_{mir} is the length of the surface described, and resres is the resolution of the map. Each matrix element, corresponding to a pixel with area res2res^{2}, contains a measure of the mirror surface height hh (with respect to a perfect spherical one).

We can associate to each mirror map (or to a part of it) the Root Mean Square (RMS) of the height, defined as:

σRMS=1ni=1n(hih¯)2withh¯=i=1nhi\sigma_{\mathrm{RMS}}=\sqrt{\frac{1}{n}\sum_{i=1}^{n}(h_{i}-\bar{h})^{2}}\qquad\mathrm{with}\quad\bar{h}=\sum_{i=1}^{n}h_{i} (14)

Another useful number to quantify surface flatness is the peak-to-valley value (PV): a measure of the difference between the highest and the lowest point.

Mirror defects can be studied in the spatial frequency domain by applying a 2D Fourier transform to the mirror map. The lowest spatial frequency fminf_{min} coincides with the inverse of lmirl_{mir}, while the maximum spatial frequency fmaxf_{max} is given by1/(2res)1/(2\cdot res). A 1D Power spectral density (PSD) can be associated with the 2D Fourier transform map hiro . For such a 1D PSD we have the relation:

σRMS2=fminfmaxPSD(f)𝑑f\sigma^{2}_{\mathrm{RMS}}=\int_{f_{min}}^{f_{max}}\mathrm{PSD}(f)\,df (15)

The low frequency defects, those which have a spatial frequency up to 103m110^{3}m^{-1}, contribute to the so-called mirror flatness while higher frequency defects are associated with the mirror roughness. This distinction has no physical motivation, but it is simply due to different techniques used to measure spatial defects in the two cases nicolas .

The scattering angle for light at normal incidence of wavelength λ\lambda can be written as a function of the frequency of spatial defect as sto :

θ=λ×f\theta=\lambda\times f (16)

This equation means that a defect at spatial frequency ff will scatter a fraction of the light at angles θ\theta or larger. As a consequence, the amount of light reflected back at normal incidence will be reduced by the same amount. This fraction is given by (4π×σ(f)/λ)2(4\pi\times\sigma(f)/\lambda)^{2} where σ(f)\sigma(f) is the amplitude of the defect at spatial frequency ff.

For a given cavity length LL and mirror diameter dd, there is a maximum scattering angle θlimit\theta_{\mathrm{limit}} above which light is scattered out of the cavity:

θlimit=d2L\theta_{\mathrm{limit}}=\frac{d}{2L} (17)

Using Eq. 16 and 17 we can then find a spatial frequency flimitf_{\mathrm{limit}} for the mirror defects above which the light is scattered out of the cavity:

flimit=d2L×λf_{\mathrm{limit}}=\frac{d}{2L\times\lambda} (18)

From the equation above, the losses due to defects with spatial frequency above flimitf_{\mathrm{limit}} can be estimated as sto :

losses(f>flimit)=(4π×σλ)2\mathrm{losses}_{(f>f_{\mathrm{limit}})}=\left(\frac{4\pi\times\sigma}{\lambda}\right)^{2} (19)

where σ\sigma is the RMS for frequencies above flimitf_{\mathrm{limit}}. For the filter cavity we are considering flimit=157m1f_{\mathrm{limit}}=157m^{-1}.

It is important to note that the RMS for frequencies lower than flimitf_{\mathrm{limit}} also contributes to losses. In fact, even if light is not immediately scattered out of the cavity, it is likely to be transferred on higher order modes and eventually exit the cavity. An accurate estimation of the round trip losses has been done using a numerical simulation of the fields in the cavity after adding realistic maps to the mirror surfaces. This allowed us to set specifications for the surface defects flatness needed to keep losses below a desired threshold.

The round trip losses in a Fabry-Pérot cavity are defined as rtl_ref :

Λrt2=PinPrPtPcirc\Lambda^{2}_{rt}=\frac{P_{in}-P_{r}-P_{t}}{P_{circ}} (20)

where PinP_{in} is the input power (which is assumed to be a fundamental mode), PcircP_{circ}, PtP_{t}, PrP_{r} are the powers circulating in the cavity, transmitted and reflected, respectively. Since we can only take advantage of the light reflected on the fundamental mode, the definition of Eq. 20 has been modified to:

Λrt2=PinPr00Pcirc\Lambda^{2}_{rt}=\frac{P_{in}-P^{00}_{r}}{P_{circ}} (21)

where Pr00P^{00}_{r} is fraction of the reflected power which is on the fundamental mode.

We used the MATLAB package OSCAR oscar to simulate the fields and compute the values of PcircP_{circ} and Pr00P^{00}_{r} to be used in Eq.21.

We ran the simulation using five different mirror maps, for mirrors used in the Virgo experiment. Four of these mirrors were produced for the initial Virgo experiment (2007-2011) with a standard polishing technology. The fifth belongs to the Advanced Virgo experiment (which will become operational in 2016) and is obtained with an ion beam polishing technique. The Virgo maps have a resolution of about 350μ350\,\mathrm{\mu}m, while the Advanced Virgo map has a resolution of 378.4μ378.4\,\mathrm{\mu}m. One example of the Virgo maps and the Advanced Virgo map are shown in Fig. 1 along with their relative PSD.

The cavity parameters used in the simulation are those reported in Tab. 2. The maps were only applied to the end mirror, while the input mirror has been considered perfect. We checked that the round trip losses for a cavity where both the mirrors have defects can be obtained by simply multiplying by two the previous result. Results presented here have already been multiplied by two.

Each surface has been characterized by its RMS and its PV over different diameters. The measured values are reported in Tab. 3. Round trip losses for the various mirrors have been calculated in terms of the radius of curvature and are reported in Fig. 2. The losses floor for each mirror has also been reported in the last column of Tab. 3 in order to be directly compared with the mirror flatness. The presence of peaks in the plots of Fig.2 is due to power transferred to higher order modes which are partially resonant along with the fundamental mode for certain values of the curvature radius.

Maps used in the simulation account for mirror defects with spatial frequency going from 10 m1m^{-1} to 2103m12\cdot 10^{3}m^{-1}. This means that losses caused by mirror roughness are not included in this estimation. A map of the the roughness has been measured for the Advanced Virgo mirror. this map, obtained by scanning an area of 0.3 mm x 0.3 mm with a resolution of 1.28μ1.28\,\mathrm{\mu}m, scans frequencies from 3.31033.3\cdot 10^{3} to 3.9105m13.9\cdot 10^{5}m^{-1}. From its RMS, under the assumption that it is uniform on the surface, we can estimate additional losses due to roughness, which should be added to those already measured. The RMS is 0.08 nm, which corresponds to 0.89 ppm of additional losses for a single reflection. For the initial Virgo mirrors, the specification on the roughness RMS was 0.1 nm which corresponds to 1.4 ppm of additional losses for a single reflection. In both cases the losses are dominated by flatness defects.The roughness map for Advanced Virgo and the relative PSD are shown in Fig.3. The measurement of the light scattered at angles larger than a few degrees gives losses of the order of 5 ppm. These include both the losses due to the roughness discussed above and those due to point defects. The corresponding additional round-trip losses will be about 10 ppm. We remark that, even including all these effects, still difference exists between the measured losses in Advanced LIGO and simulation results. Losses due to scattering at angles between mrad and a few degrees are being investigated as a possible cause of these differenceshiroprivate . These hypothetical losses are not included in this paper.

The conclusions of this study are that, for his filter cavity (length 300300 m, mirror diameter 1010 cm, RoC 400\sim 400 m):

  • An Advanced Virgo-class mirror will produce floor losses <10<10 ppm and a Virgo-class mirror will produce losses 4080\sim 40-80 ppm. In order to determine the final specifications on the mirror flatness, the squeezing degradation given by the cavity losses has to be compared to the other degradation mechanisms. This analysis is performed in the next section.

  • The accidental degeneracy can amplify the losses by more than an order of magnitude. The simulation gives the safe regions, where the losses are at the floor level.

  • The precise RoC value should be chosen in some of the floor losses regions. A precision on the RoC of 1%\sim 1\% is necessary to guarantee the RoC to be in these regions.

Refer to caption
Figure 1: Initial Virgo map (top) and Advanced Virgo map (bottom). Mirrors maps (left), PSD (right).
diameter
0.10 m
diameter
0.05 m
diameter
0.02 m
diameter
0.01 m
Mirror
RMS
(nm)
PV
(nm)
RMS
(nm)
PV
(nm)
RMS
(nm)
PV
(nm)
RMS
(nm)
PV
(nm)
Losses
(ppm)
V1 2.617 15.95 1.424 9.46 0.687 6.04 0.558 5.38 57.8
V2 1.875 15.64 1.234 8.56 0.682 6.29 0.812 5.92 80.6
V3 2.499 15.34 1.360 10.51 0.754 4.31 0.430 3.31 39.8
V4 1.752 45.61 0.984 12.12 0.509 4.46 0.531 4.46 42.6
ADV 0.319 2.99 0.274 2.09 0.192 1.18 0.142 0.97 5.6
Table 3: RMS and PV (over different diameters) and the round trip losses floor for each mirror map. The values indicated for the losses correspond to the floor of Fig.4.
Refer to caption
Figure 2: Round trip losses as a function of the radius of curvature. Peaks correspond to values of RoC for which the cavity is quasi-degenerate.
Refer to caption
Figure 3: Roughness maps for the Advanced Virgo configuration. Mirror map (left), PSD (right).

Mirror dimensions

Refer to caption
Figure 4: Round trip losses as a function of RoC for different values of the mirror diameter. Peaks which correspond to cavity degeneracies are reduced for smaller mirrors while the floor of round trip losses increases.

Choosing the best mirror dimension is not as straightforward as it may seem to be. The scattering mechanisms described in the previous paragraph show that bigger mirrors have lower levels of losses. In fact, we see from Eq.18 that by increasing the mirror diameter dd, the minimum spatial frequency flimitf_{limit} of defects which scatter light out of the cavity is higher. Consequently, the RMS for frequencies above flimitf_{limit} in Eq.19 is reduced and so too the losses. However this is not the only effect to be taken into account. We have already observed that for certains values of the curvature radius, the cavity can be degenerate. This means that the separation between the resonance frequency of the fundamental mode and that of a higher order mode is small enough to make it partially resonant. Some power of the fundamental mode is then transferred to this higher order mode, and losses in the fundamental mode are remarkably increased. Critical RoC values are highlighted by simulation and correspond to the peak observed in Fig.2. Mirror dimensions also have a strong impact on the appearance of such peaks. In Fig.4, round trip losses for a virgo mirror (V3) are shown as a function of the RoC for different values of the mirror diameter. We see that for bigger diameters more peaks are observed, i.e. there are more RoC values which make the cavity degenerated. This number is reduced for smaller mirrors. This effect can be possibly explained by considering the intensity profile of higher order modes. In fact, the power of higher mode is spread on a bigger surface than the fundamental mode. Generally, the width of a mode increases with its order, and then, a reduction of the mirror dimension prevents wider modes from resonating. This explanation is confirmed by the fact that a gradual reduction of mirror dimension first eliminates resonances of the modes with higher nn. Using smaller mirror will reduce the number of peaks, while increasing the floor losses level according to the mechanism explained at the beginning of the paragraph. Therefore mirror dimensions should be chosen in order to strike the best balance between low floor losses and the presence of a safe zone for the RoC reasonably far from degeneracies. Using smaller mirrors allowed us to relax accuracy requirements on the RoC value. We can see from Fig. 4 that a mirror diameter of 0.075 m allows us to pick a RoC, for example of 420, for which losses remain basically constant in a range of 20\sim 20 m. Therefore the required precision on the RoC is 5%\sim 5\%. For such a mirror dimension the contribution of clipping losses to cavity losses are still negligible. An initial value for the mirror dimension has been set to 0.1 m. This was the diameter of the former TAMA mirrors and it will allow the reuse of part of the suspension system already developed for TAMA. If needed, diaphragms can be placed in front of the mirror to reduce their diameter according to what we have observed.

Simple round trip simulation

A complete simulation of the cavity has been used to compute fields in our system and then to evaluate round trip losses, according to Eq.21. This simulation allows us to take into account the effect of higher order mode resonance. In this case, light does not exit the cavity but is partially transferred to a higher order mode. This effect is observable by comparing the round trip losses on the fundamental mode with those in all modes (i.e the total amount of light exiting the cavity).Coinciding with resonance, the curves relative to the two cases show a discrepancy accounting for the light which is still in the cavity but not on the fundamental mode. On the other hand, when the cavity is not degenerate, the total amount of light exiting the cavity coincides with the light lost on the fundamental mode. This quantity corresponds to the floor losses level reported in Tab. 4 and has been compared with that obtained by simply computing the power escaping the mirror aperture after a single roundtrip (reflection from a mirror with real map, propagation for 300 m, then reflection again from a perfect mirror (as in the simulated cavity) and propagating again for 300 m). In practice, we measure the lost power after a cavity round trip of the beam. The comparison between losses obtained with the complete simulation and those found with the simple round trip are shown in Tab. 4 for different mirrors maps and for different values of the diameter and shows a good agreement. Even if the second method is less accurate and cannot be used in the case of degeneracy, it is much faster and can be employed to obtain a rough estimation of the floor level of the round trip losses in the cavity. A plot of the light power exiting cavity after the first reflection is shown in Fig. 5.

Mirror Diameter RTL - full sim RTL - quick sim
V1 10 cm 57.8 ppm 57.6 ppm
V2 10 cm 80.6 ppm 79.4 ppm
V4 10 cm 42.6 ppm 40.4 ppm
ADV 10 cm 5.6 ppm 5.6 ppm
V3 10 cm 39.8 ppm 38.8 ppm
V3 7.5 cm 50.4 ppm 50.0 ppm
V3 6.0 cm 62.4 ppm 62.0 ppm
V3 5.0 cm 168.6ppm 165.4 ppm
Table 4: Comparison between losses obtained with the complete simulation and those found with simple round method for different mirrors maps and for different value of the diameter. Results of the quick simulation have been multiplied by two as in the previous case.
Refer to caption
Figure 5: Amplitude of the field scattered out of the cavity by high spatial frequency defects. The field is observed after being reflected from a mirror with a real map and then propagated for 300 m.

IV Squeezing degradation and decoherence estimation

The quantum noise in an interferometer, normalized with respect to shot noise, can be simply expressed as

N(Ω)=1+K2(Ω)N(\Omega)=1+K^{2}(\Omega) (22)

where KK is the optomechanical coupling defined in Eq.2.

In an ideal system, the injection of a frequency dependent squeezed vacuum from the interferometer dark port will reduce the quantum noise to

N(Ω)=e2σ(1+K2(Ω))N(\Omega)=e^{-2\sigma}(1+K^{2}(\Omega)) (23)

where σ\sigma is connected with the squeezing magnitude usually expressed in decibel by σdB=20σ×log10e\sigma_{\mathrm{dB}}=-20\,\sigma\times\log_{10}e.

In a real setup, two factors prevent this optimal noise reduction: first, optical losses will decrease the squeezing level, introducing a non-squeezed vacuum; second, fluctuations of the squeezing angle will preclude an optimal rotation of the squeezed state.

In sq2 a detailed analysis of several of these mechanisms has been applied to a 16 m filter cavity, with round trip losses of 1 ppm/m, which is considered a possible short-term solution for Advanced LIGO sq1 . The same analysis is performed here for the 300 m filter cavity, with round trip losses of 80 ppm, corresponding to a conservative estimate for Virgo-class quality mirrors. To ease the comparisons between the two cases, the numerical values for other sources of squeezing degradation are exactly the same of sq2 , as reported in Tab. 5.

Figure 6 represents the squeezing degradation budget for the 300 m filter cavity. It shows the ratio between the quantum noise of a dual recycled Fabry-Pérot Michelson interferometer without squeezing (for instance, initial KAGRA) and the quantum noise in the presence of frequency dependent-squeezing. An initial realistic squeezing level of 9 dB has been considered and the various degradation mechanisms have been taken into account separately and combined (black curve). In this analysis, as for sq2 , the contribution of the interferometer losses has been neglected. The squeezing degradation mechanisms considered are (for a detailed description see sq2 ):

Filter cavity losses

The optical losses in the filter cavity spoil the squeezing in two ways: firstly, they corrupt squeezing with anti-squeezing, mixing the two squeezing quadratures. Secondly, they mix standard vacuum with squeezed vacuum. For a 16 m cavity, the filter cavity losses represent the main contribution to squeezing degradation up to 100-200 Hz. Since this effect depends on the round trip losses per meterKhalili1 , it is considerably reduced in a 300 m cavity with round trip losses of 80 ppm, and at low frequencies becomes comparable with that of the mode mismatching. For this reason it is not extremely useful to further reduce filter cavity losses by increasing the mirror quality (for example using Advanced Virgo-class mirrors), unless mode matching is substantially improved.

Injection and readout losses

Injection losses, Λinj2\Lambda^{2}_{\mathrm{inj}}, (caused by scattering, absorption and imperfections in the optics) and readout losses, Λro2\Lambda^{2}_{\mathrm{ro}}, (from the interferometer to the readout, including the photodetector quantum efficiency) cause a squeezing degradation by mixing ordinary vacuum with squeezed vacuum. Being independent of the cavity length, their impact does not change with a longer cavity. This mechanism is the dominating source above 100-200 Hz, assuming a losses value of 5%5\% both for injection and readout losses. In this region, quantum noise is by far the limiting noise: a reduction in injection/readout losses will lead to a consistent improvement of the detector sensitivity

Mode mismatching

Following the analysis shown in sq2 , a squeezing degradation is also determined by an imperfect mode matching between the squeezed field and the cavity mode (ΛmmFC2\Lambda^{2}_{\mathrm{mmFC}}), and between the cavity mode and the local oscillator (ΛmmLO2\Lambda^{2}_{\mathrm{mmLO}}). This mismatching allows part of the field to bypass the cavity without experiencing frequency rotation, and are also a source of losses.

The magnitude of the mode mismatching can be easily measured. Nevertheless, the amplitude of the squeezing degradation depends of an arbitrary phase which is difficult to quantify . For this reason, in Fig.2 we have shown the worst case scenario.

As in the case of injection and readout losses, this effect does not depend on the filter cavity length and, for a 300 m filter cavity with a RTL of about 80 ppm, it is comparable with the degradation due to filter cavity losses. The estimation is done assuming a mismatch of 2%2\% between squeezed injected field and filter cavity modes and a mismatch of 5%5\% between injected field and the local oscillator.

Frequency dependent Phase Noise

A length noise of the filter cavity (possibly caused by seismic noise or control noise) δL\delta L results in a shift of the optimal detuning δΔωfc\delta\Delta\omega_{\mathrm{fc}} given by:

δΔωfc=ω0LδL\delta\Delta\omega_{\mathrm{fc}}=\frac{\omega_{0}}{L}\delta L (24)

This compromises an optimal squeezing quadrature rotation, limiting the achievable noise reduction. In a 300 m cavity, assuming a δL\delta L (RMS) of about 0.3 pm, this effect becomes completely negligible with respect to other mechanisms.

Refer to caption
Figure 6: Squeezing degradation budget. Quantum noise relative to coherent vacuum in the signal quadrature for a ideal system (blue curve) is compared with the one obtained taking into account degradation mechanisms (one by one).
Parameter Symbol Value
Filter cavity losses Λrt2\Lambda^{2}_{\mathrm{rt}} 8080 ppm
Injection losses Λinj2\Lambda^{2}_{\mathrm{inj}} 5%5\%
Readout losses Λro2\Lambda^{2}_{\mathrm{ro}} 5%5\%
Mode-mismatch squeezer-filter cavity ΛmmFC2\Lambda^{2}_{\mathrm{mmFC}} 2%2\%
Mode-mismatch squeezer-local oscillator ΛmmLO2\Lambda^{2}_{\mathrm{mmLO}} 5%5\%
Filter cavity length noise (RMS) δLfc\delta L_{\mathrm{fc}} 0.30.3 pm
Injected squeezing σdB2\sigma^{2}_{\mathrm{dB}} 9dB9\,\mathrm{dB}
Table 5: Parameters used in the estimation of squeezing degradation.

V Improvement in KAGRA sensitivity

This estimation of the achievable level of frequency-dependent squeezing using a 300 m filter cavity can be used to quantify the related improvement in KAGRA sensitivity. In Fig. 7 the quantum noise for KAGRA, without squeezing, is compared with the quantum noise obtained using 9 dB of frequency-dependent squeezed light, when all degradation mechanisms previously described are taken into account. We considered both the case of a filter cavity with round trip losses of 80 ppm and that of a perfect filter cavity. The comparison shows that no major improvements can be obtained by reducing round trip losses under the level of 80\sim 80 ppm since their effect becomes comparable with that of other degradation mechanisms.

Refer to caption
Figure 7: Quantum noise for KAGRA without squeezing, compared with the quantum noise using 9 dB frequency-dependent squeezing, both in the ideal system and when all the degradation mechanisms are taken into account. We remark that quantum noise without squeezing is relative to official KAGRA sensitivity using a configuration with a homodyne detection angle of 121.8, while quantum noise in the presence of squeezing uses a standard homodyne angle of 90.
Refer to caption
Figure 8: Improvement in KAGRA sensitivity using 9 dB frequency-dependent squeezing, considering lossy cavity and other degradation mechanisms.
Refer to caption
Figure 9: The quantum noise in the presence of 9 dB squeezing and lossy system (filter cavity RTL 80 ppm) is compared with the other noise sources. Note that below 100 Hz, the contribution from thermal noise would prevent an improvement in the total sensitivity even in case a further reduction of quantum noise.

Fig. 8 shows the improvement in KAGRA sensitivity using 9 dB frequency-dependent squeezing, considering a filter cavity with round trip losses of 80 ppm and other degradation mechanisms. We remark that the use of squeezing allows us to reach a sensitivity beyond the standard quantum limit around 7070 Hz. In Fig. 9 the quantum noise of a realistic lossy system is shown along with other KAGRA noise sources. We observe how a reduction in the only quantum noise will result in an improvement in almost the whole KAGRA observation bandwidth.

We also remark that:

  • In the frequency region below 100 Hz, thermal noise is close to quantum noise and there is little to be gained from a further significant reduction in quantum noise (obtainable by improving mismatching, injection/readout losses and decreasing losses in the filter cavity).

  • In the frequency region above 100 Hz, which is dominated by quantum noise, there is much more room for improvements. However, a reduction of the filter cavity optical losses would not provide a higher squeezing level, since in this region the squeezing degradation is mainly caused by injection and readout losses.

This suggests that a further reduction of the filter cavity losses would not be necessary, while a major benefit can be obtained by protecting squeezing from losses due to injection, detection and mismatching.

VI Summary

We have presented the optical design of a 300 m filter cavity used for the KAGRA experiment. The cavity will be tested at NAOJ, inside the TAMA infrastructure. First, given KAGRA parameters, we have found the detuning and finesse values needed to produce an optimal rotation of the squeezing angle. In order to find the surface quality needed for the filter cavity, we have computed the round trip losses using a numerical simulation with realistic mirror maps. The test bench maps used are those of Virgo and Advanced Virgo.

An analysis of the squeezing deterioration mechanism shows that for a round trip loss value of 80 ppm, corresponding to a conservative estimate for Virgo-class mirrors, the squeezing degradation due to the filter cavity are comparable or lower than contributions from the cavity mismatching and injection/detection losses. Moreover frequency-dependent phase noise becomes completely negligible.

We then computed the improvements in KAGRA sensitivity with a 9 dB frequency dependent squeezing and realistic loss mechanisms. We found a sensitivity improvement in almost the full KAGRA signal bandwidth, with a factor 2\sim 2 at high frequency. As already mentioned, the interferometer internal losses have been neglected in this analysis. In order to have a more precise estimation of the sensitivity improvement achievable using frequency dependent squeezing, the contribution of these losses should be estimated.

We have also shown that, without an improvement in other noise sources, a further reduction of the filter cavity losses will not lead to a considerable improvement in the detector sensitivity.

The results of this work can be easily extended to any gravitational-wave interferometric detector planning the use of a 100-m class filter cavity, and in particular for a medium term upgrade of Advanced Virgo and for Einstein Telescope.

Acknowledgements

We would like to thank Lisa Barsotti, John Miller and Matteo Tacca for useful discussions. This work was supported by the JSPS Grant-in-Aid for Scientific Research the JSPS Core-to-Core Program, A. Advanced Research Networks and the European Commission under the Framework Program 7 (FP7) ’People’, project ELiTES (grant agreement 295153). E.C. is supported by the European Gravitational Observatory.

References

  • (1) Y. Aso et al. Kagra collaboration, Phys. Rev. D 88, 043007 (2013).
  • (2) The LIGO Scientific Collaboration, Advanced LIGO, Class. Quantum Grav. 32 074001 (2015)
  • (3) The Virgo Collaboration, Advanced Virgo: a 2nd generation interferometric gravitational wave detector, Class. Quantum Grav. 32 024001 (2015)
  • (4) C. M. Caves ”Quantum-mechanical noise in an interferometer” Phys. Rev. D 23, 1693 (1981)
  • (5) H. J. Kimble et al., Phys. Rev. D 65, 022002 (2001)
  • (6) S. Chelkowski et al., ” Experimental characterization of frequency-dependent squeezed light ”Phys.Rev. A 71, 013806 (2005)
  • (7) E. Oelker et al., ” Audio-band frequency-dependent squeezing ” arXiv:1508.04700 (2015)
  • (8) M. Ando et al., Phys. Rev. Lett 86, 3950 (2001)
  • (9) P. Kwee et al.,”Decoherence and degradation of squeezed states in quantum filter cavities”, Phys. Rev. D 90, 062006 (2014)
  • (10) F. Ya. Khalili, ”Optimal configurations of filter cavity in future gravitational-wave detectors”, Phys. Rev. D 81, 122002 (2010)
  • (11) J. Harms et al., ” Squeezed-input, optical-spring, signal-recycled gravitational-wave detectors ” Phys.Rev. D68, 042001 (2003)
  • (12) J.C. Stover, Optical Scattering: Measurement and Analysis (1995)
  • (13) V.B.Braginsky and F.Khalili, ”Quantum measurement”, Cambridge University Press
  • (14) Advanced Virgo Squeezing Working Group, ”Advanced Virgo Squeezer Technical Design Report”, Virgo internal note, 2015
  • (15) M.Abernathy et al., Einstein gravitational wave Telescope conceptual design study, http://www.et-gw.eu/etdsdocument
  • (16) F.Magaña-Sandoval et al., ” Large-angle scattered light measurements for quantum-noise filter cavity design studies ” J. Opt. Soc. Am. A / Vol. 29, No. 8 (2012)
  • (17) J. Degallaix, ”OSCAR a Matlab based optical FFT code” in IOP proceedings of Journal of Physics: Conference Series (2010)
  • (18) H. Yamamoto, Private comunication
  • (19) H. Yamamoto, ”1D PSD of mirror maps”, LIGO Internal Note, LIGO-T1100353-v1 (2011)
  • (20) J.Degallaix et al., ”Defining the arm cavity loss for Advanced Virgo”, Virgo internal note, VIR-706A-10
  • (21) N. Straniero et al., ”Realistic loss estimation due the mirror surfaces in a 10 meters-long high finesse Fabry-Pérot filter-cavity”, Opt. Express 23, 21455-21476 (2015)
  • (22) M. Evans et al., ”Realistic filter cavities for advanced gravitational wave detectors ”, Phys. Rev. D 88, 022002 (2013)